The impact of passive cooling of the experimental house on indoor air velocities
Popis výsledku v původním jazyce
A set of measurements was performed in the experimental house in order to investigate the air velocities and the draft risk in the rooms during passive cooling. The hot-sphere anemometers with the air velocity range of 0.05 - 1 m/s were used for the measurements. The velocities in the air inlets were measured with the anemometer that had a range of 0.1 - 30 m/s. The indoor air velocities were measured at various locations at the height of 0.1 m, 1.1 m, and 1.6 m above the floor level. The 15 second averages of air velocities were recorded in the measurements. The air velocities above the beds were also investigated because passive cooling usually takes place at night. The measured indoor air velocities were relatively low, rarely exceeding 0.3 m/s. Thehighest velocities occurred at the floor level. Relatively high air velocities were observed in the vicinity of the inlets, but people are not very likely to stay close to the inlets (particularly at night). The air velocities exceeding
Název v anglickém jazyce
The impact of passive cooling of the experimental house on indoor air velocities
Popis výsledku anglicky
A set of measurements was performed in the experimental house in order to investigate the air velocities and the draft risk in the rooms during passive cooling. The hot-sphere anemometers with the air velocity range of 0.05 - 1 m/s were used for the measurements. The velocities in the air inlets were measured with the anemometer that had a range of 0.1 - 30 m/s. The indoor air velocities were measured at various locations at the height of 0.1 m, 1.1 m, and 1.6 m above the floor level. The 15 second averages of air velocities were recorded in the measurements. The air velocities above the beds were also investigated because passive cooling usually takes place at night. The measured indoor air velocities were relatively low, rarely exceeding 0.3 m/s. Thehighest velocities occurred at the floor level. Relatively high air velocities were observed in the vicinity of the inlets, but people are not very likely to stay close to the inlets (particularly at night). The air velocities exceeding
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA103%2F07%2F0907" target="_blank" >GA103/07/0907: Využití solárních komínů a materiálů se změnou skupenství pro pasivní chlazení budov</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXVI. Setkání kateder mechaniky tekutin a termomechaniky - Sborník z mezinárodní vědecké konference.
ISBN
80-86786-09-9
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
33-34
Název nakladatele
ČVUT Praha
Místo vydání
Praha
Místo konání akce
Herbertov
Datum konání akce
28. 8. 2007
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—