Vliv nastavení systému PDA na výsledné charakteristiky spreje
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F07%3APU70703" target="_blank" >RIV/00216305:26210/07:PU70703 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The influence of the PDA setup on resultant spray characteristics
Popis výsledku v původním jazyce
The paper deals with the comparison of the velocity-size distribution results acquired at different geometrical setups of the PDA (Phase Doppler Anemometer) system. The PDA is well known as one of the most useful techniques to study the particle velocityand size distributions in two-phase flows. The value of the Off-axis angle affects the number of the detected particles in the spray. Experiments were carried out on the sprays generated by both effervescent and pressure nozzles. During the experiment,the effervescent nozzle was operated in the air pressure range of 0.1 to 0.5 MPa and GLR (Gas-to-liquid mass ratio) varied from 1 to 25%. Mass flow rates of water ranged from 5 up to 50 gos-1. The pressure nozzles were operated in the same range of pressure level and flow rates as applied to the effervescent nozzle experiments. The measurement of spray quality is represented by the values of the mean diameters of droplets, especially D32 (SMD-Sauter mean diameter). The setup of the PDA s
Název v anglickém jazyce
The influence of the PDA setup on resultant spray characteristics
Popis výsledku anglicky
The paper deals with the comparison of the velocity-size distribution results acquired at different geometrical setups of the PDA (Phase Doppler Anemometer) system. The PDA is well known as one of the most useful techniques to study the particle velocityand size distributions in two-phase flows. The value of the Off-axis angle affects the number of the detected particles in the spray. Experiments were carried out on the sprays generated by both effervescent and pressure nozzles. During the experiment,the effervescent nozzle was operated in the air pressure range of 0.1 to 0.5 MPa and GLR (Gas-to-liquid mass ratio) varied from 1 to 25%. Mass flow rates of water ranged from 5 up to 50 gos-1. The pressure nozzles were operated in the same range of pressure level and flow rates as applied to the effervescent nozzle experiments. The measurement of spray quality is represented by the values of the mean diameters of droplets, especially D32 (SMD-Sauter mean diameter). The setup of the PDA s
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F06%2F0750" target="_blank" >GA101/06/0750: Effervescent dvoumediové trysky s vnitřním směšováním</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Experimental fluid mechanics 2007 - Conference Proceedings
ISBN
978-80-7372-273-9
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
93-97
Název nakladatele
Neuveden
Místo vydání
Liberec
Místo konání akce
Liberec
Datum konání akce
28. 11. 2007
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—