Computational Modelling of the Biomechanical Systems Properties
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F07%3APU78456" target="_blank" >RIV/00216305:26210/07:PU78456 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computational Modelling of the Biomechanical Systems Properties
Popis výsledku v původním jazyce
The part of the project is aimed at determining the dependencies of the abrasion on the mechanical properties of the total endoprosthesis (TEP), or of the mechanical properties and their behaviour in contact with TEP. The size of abrasion for the given type of the endoprosthesis can be determined by means of experiments only. Mechanical quantities describing the features of the contact between two bodies (process of contact pressure, size of contact area) can be determined effectively only by calculation that enables generalization of the obtained results and thanks to that it raises their importance for the clinical practice. Therefore the computational modelling of the contact pressure distribution at a physiological hip joint and its comparison withthe case, when the surface or total artificial joint was used, was implemented in 2006. Possible shape deviations in the connection between head and acetabulum were considered with the total endoprosthesis. Material characteristics used
Název v anglickém jazyce
Computational Modelling of the Biomechanical Systems Properties
Popis výsledku anglicky
The part of the project is aimed at determining the dependencies of the abrasion on the mechanical properties of the total endoprosthesis (TEP), or of the mechanical properties and their behaviour in contact with TEP. The size of abrasion for the given type of the endoprosthesis can be determined by means of experiments only. Mechanical quantities describing the features of the contact between two bodies (process of contact pressure, size of contact area) can be determined effectively only by calculation that enables generalization of the obtained results and thanks to that it raises their importance for the clinical practice. Therefore the computational modelling of the contact pressure distribution at a physiological hip joint and its comparison withthe case, when the surface or total artificial joint was used, was implemented in 2006. Possible shape deviations in the connection between head and acetabulum were considered with the total endoprosthesis. Material characteristics used
Klasifikace
Druh
C - Kapitola v odborné knize
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název knihy nebo sborníku
Simulation Modelling of Mechatronic Systems II
ISBN
978-80-214-3559-9
Počet stran výsledku
12
Strana od-do
—
Počet stran knihy
256
Název nakladatele
VUT v Brně
Místo vydání
Brno
Kód UT WoS kapitoly
—