Redukce perzistentních látek
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F07%3APU81133" target="_blank" >RIV/00216305:26210/07:PU81133 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Reduction of Persistent Pollutants Emissions
Popis výsledku v původním jazyce
Generation of wide range of harmful compounds as a result of waste incineration represents a problem which has to be solved in agreement with environmental regulations. Flue gas contains the following groups of harmful compounds: persistent organic pollutants (POP), especially enormously toxic polychlorinated dibenzo-p-dioxins a polychlorinated dibenzo-furans (PCDD/F). Based on experience from operation of the incinerator with capacity of 96,000 t/y it has been proved that even after more than three year's operation the activity of filtration material was not decreased and efficiency of dioxins removal from flue gas ranges from 97 to 99 %. These facts come from complex measurements where concentration of PCDD/F toxic congeners in both flue gas and separated flying ash was measured. We arrived at confirming expected assumptions that various congeners are not decomposed uniformly in the dioxin filter and the stage of their decomposition depends on their representation in the gas phase. I
Název v anglickém jazyce
Reduction of Persistent Pollutants Emissions
Popis výsledku anglicky
Generation of wide range of harmful compounds as a result of waste incineration represents a problem which has to be solved in agreement with environmental regulations. Flue gas contains the following groups of harmful compounds: persistent organic pollutants (POP), especially enormously toxic polychlorinated dibenzo-p-dioxins a polychlorinated dibenzo-furans (PCDD/F). Based on experience from operation of the incinerator with capacity of 96,000 t/y it has been proved that even after more than three year's operation the activity of filtration material was not decreased and efficiency of dioxins removal from flue gas ranges from 97 to 99 %. These facts come from complex measurements where concentration of PCDD/F toxic congeners in both flue gas and separated flying ash was measured. We arrived at confirming expected assumptions that various congeners are not decomposed uniformly in the dioxin filter and the stage of their decomposition depends on their representation in the gas phase. I
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/OE%20200" target="_blank" >OE 200: Optimalizace systému čištění spalin s bezpečným a spolehlivým snižováním emisí dioxinů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2007
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10 th Conference on Process Integration, Modelling and Optimisation for Energy Saving and Pollution Reduction PRES 20007 - Volume 2
ISBN
88-901915-4-6
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Ischia Porto
Datum konání akce
24. 6. 2007
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—