Energy consumption of the Aaberg exhaust hood compared with a flanged hood
Popis výsledku v původním jazyce
The article focuses on local exhaust ventilation, Aaberg exhaust hood, especially. As air is supplied by the hood, an assessment of energy consumption has been carried out to find out how it compares with a flanged exhaust hood. The study covered the investigation of the velocity drop along the principal hood axis that was taken as the measure of the suction effect of the hood, and the pressure drop associated with the flow through the device hence power input required to meet a particular capture velocity at a particular distance from the hood opening. Based on the variation of the operational parameters of the hood, namely, flow rates and the momentum fluxes ratios, it has been found out the Aaberg exhaust hood compares favourably with the flanged hood. Although the hood performance is superior to the standard hood, the superiority is constrained by critical parameters that have been identified.
Název v anglickém jazyce
Energy consumption of the Aaberg exhaust hood compared with a flanged hood
Popis výsledku anglicky
The article focuses on local exhaust ventilation, Aaberg exhaust hood, especially. As air is supplied by the hood, an assessment of energy consumption has been carried out to find out how it compares with a flanged exhaust hood. The study covered the investigation of the velocity drop along the principal hood axis that was taken as the measure of the suction effect of the hood, and the pressure drop associated with the flow through the device hence power input required to meet a particular capture velocity at a particular distance from the hood opening. Based on the variation of the operational parameters of the hood, namely, flow rates and the momentum fluxes ratios, it has been found out the Aaberg exhaust hood compares favourably with the flanged hood. Although the hood performance is superior to the standard hood, the superiority is constrained by critical parameters that have been identified.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 11th International Conference on Indoor Air Quality and Climate
ISBN
978-87-7877-270-1
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
DTU - Lyngby
Místo vydání
Copenhagen, Denmark
Místo konání akce
Copenhagen
Datum konání akce
17. 8. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—