The paper deals with the problems of ceramic head of hip joint endoprosthesis destructions in vivo, and with assessing the impact of shape deflections of conical surfaces on the tensile stress in the head. There are assumed two material characteristics of the stem - the first is linear elastic and the second is bilinear plastic modelled austenitic steel used in the bio-implants. Concerned are shape deviations from the ideal conical surfaces of the stem and the head of the endoprosthesis. The shape deviations may be modelled at the macro-level - this concerns model shape inaccuracies such as deviation from the nominal degree of taper, at the micro-level - when the stochastic distribution of unevenness on the contact areas is respected. The problem of stress in ceramic heads was solved using the algorithm of the finite element method - system ANSYS under ISO 7206-5 loading. In the paper are presented and analysed the results of solution of the macro-level shape deviations and micro-level
Název v anglickém jazyce
Stress Analysis of the Ceramics Head with Micro and Macro Shape Deviations of the Contact Areas
Popis výsledku anglicky
The paper deals with the problems of ceramic head of hip joint endoprosthesis destructions in vivo, and with assessing the impact of shape deflections of conical surfaces on the tensile stress in the head. There are assumed two material characteristics of the stem - the first is linear elastic and the second is bilinear plastic modelled austenitic steel used in the bio-implants. Concerned are shape deviations from the ideal conical surfaces of the stem and the head of the endoprosthesis. The shape deviations may be modelled at the macro-level - this concerns model shape inaccuracies such as deviation from the nominal degree of taper, at the micro-level - when the stochastic distribution of unevenness on the contact areas is respected. The problem of stress in ceramic heads was solved using the algorithm of the finite element method - system ANSYS under ISO 7206-5 loading. In the paper are presented and analysed the results of solution of the macro-level shape deviations and micro-level
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Human biomechanics 2008
ISBN
978-80-01-04163-5
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Neuveden
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
29. 9. 2008
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—