Effervescent Atomizér: vliv provozních podmínek a vnitřnígeometrie na strukturu spreje; Studie s použitím PIV-PLIF
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F08%3APU78989" target="_blank" >RIV/00216305:26210/08:PU78989 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effervescent Atomizer: Influence of the Operation Conditions and Internal Geometry on Spray Structure; Study Using PIV-PLIF
Popis výsledku v původním jazyce
A single-hole effervescent atomizer spraying light heating oil (LHO) with air as an atomizing medium in the outside-in gas injection configuration is studied. Influence of operation conditions and atomizer design parameters on spray structure is described. Inlet air gauge pressure and gas-to-liquid-ratio by mass (GLR) are varied. Several design parameters are modified: size and number of aeration holes, their location, diameter of the mixing chamber and shape of discharge orifice. 2D velocity field of droplets in the spray and distribution of liquid phase concentration in the plane of the exit orifice axis are evaluated using PIV-PLIF. Results show relatively small influence of the atomizer design on droplet velocity profile and on the concentration distribution. Droplet velocity and concentration data is used for calculation of mass flux and resulting spray cone angle The spray cone half-angle has a value in the range 6.5 to 9.3 deg for all measured configurations and operation condit
Název v anglickém jazyce
Effervescent Atomizer: Influence of the Operation Conditions and Internal Geometry on Spray Structure; Study Using PIV-PLIF
Popis výsledku anglicky
A single-hole effervescent atomizer spraying light heating oil (LHO) with air as an atomizing medium in the outside-in gas injection configuration is studied. Influence of operation conditions and atomizer design parameters on spray structure is described. Inlet air gauge pressure and gas-to-liquid-ratio by mass (GLR) are varied. Several design parameters are modified: size and number of aeration holes, their location, diameter of the mixing chamber and shape of discharge orifice. 2D velocity field of droplets in the spray and distribution of liquid phase concentration in the plane of the exit orifice axis are evaluated using PIV-PLIF. Results show relatively small influence of the atomizer design on droplet velocity profile and on the concentration distribution. Droplet velocity and concentration data is used for calculation of mass flux and resulting spray cone angle The spray cone half-angle has a value in the range 6.5 to 9.3 deg for all measured configurations and operation condit
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA101%2F06%2F0750" target="_blank" >GA101/06/0750: Effervescent dvoumediové trysky s vnitřním směšováním</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2008
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
22 Annual Conference on Liquid Atomization and Spray Systems
ISBN
978-88-903712-0-2
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Politecnico di Milano
Místo vydání
Como Lake, Italy
Místo konání akce
Como Lake, Itálie
Datum konání akce
8. 9. 2008
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—