Součinitele přestupu tepla pod vodními chladicími tryskami pro sochorové kontilití
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F09%3APU81262" target="_blank" >RIV/00216305:26210/09:PU81262 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
HEAT TRANSFER COEFFICIENTS BENEATH THE WATER COOLING NOZZLES OF A BILLET CASTER
Popis výsledku v původním jazyce
The accuracy with which the solidification and cooling of a continuously cast billet is investigated depends on the setting of the boundary conditions of the numerical model of the temperature field. An in-house numerical model of the 3D temperature field of a concast billet had been used. This model enables the analysis of the temperature field of the actual blank as it passes through the zero-, primary-, secondary- and tertiary-cooling zones. This paper deals with the derivation of transfer phenomenaunder the cooling nozzles of the secondary zone. These phenomena are expressed by the values of the heat transfer coefficients (HTCs). The dependences of these coefficients on surface temperature and other operational parameters must also be given. Regarding the fact that on a real caster, where there are many types of nozzles positioned inside a closed cage, it is practically impossible to conduct measurement of the real boundary conditions. Therefore, an experimental laboratory device
Název v anglickém jazyce
HEAT TRANSFER COEFFICIENTS BENEATH THE WATER COOLING NOZZLES OF A BILLET CASTER
Popis výsledku anglicky
The accuracy with which the solidification and cooling of a continuously cast billet is investigated depends on the setting of the boundary conditions of the numerical model of the temperature field. An in-house numerical model of the 3D temperature field of a concast billet had been used. This model enables the analysis of the temperature field of the actual blank as it passes through the zero-, primary-, secondary- and tertiary-cooling zones. This paper deals with the derivation of transfer phenomenaunder the cooling nozzles of the secondary zone. These phenomena are expressed by the values of the heat transfer coefficients (HTCs). The dependences of these coefficients on surface temperature and other operational parameters must also be given. Regarding the fact that on a real caster, where there are many types of nozzles positioned inside a closed cage, it is practically impossible to conduct measurement of the real boundary conditions. Therefore, an experimental laboratory device
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F09%2F0940" target="_blank" >GA106/09/0940: Numerický a stochastický model plynule odlévaných ocelových předlitků obdélníkového profilu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
18th International Conference on Metalurgy and Materials
ISBN
978-80-87294-10-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
Tanger Ltd.
Místo vydání
Hradec nad Moravicí
Místo konání akce
Hradec nad Moravicí
Datum konání akce
19. 5. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—