Sress distribution around tread profile of dental implant
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F09%3APU83425" target="_blank" >RIV/00216305:26210/09:PU83425 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sress distribution around tread profile of dental implant
Popis výsledku v původním jazyce
This work is specialized to stress-strain deformation analysis of dental implant. Failures of osseointegrated implants have been associated with many factors, such as poor bone quality, lack of initial instability, overloading and fractures of implants and abutment screws. Fracture of these elements may be related with a poor fit of the framework, which leads to material fatigue, occlusal overload and intrinsic material failures. The purpose of this study was to analyze the influence of implant diameterand length on stress distribution and to analyze overload risk of clinically evidenced crestal bone loss at the implant neck in mandibular molar periimplant region. Stress-based performances of 4 implants (2 Nobel Biocare, Brĺnemark, and metric implant)were analyzed by linearly elastic 3-dimensional finite element simulations, under a static load. The masticatory load was simulated using an average masticatory force in a natural direction, oblique to the occlusal plane.
Název v anglickém jazyce
Sress distribution around tread profile of dental implant
Popis výsledku anglicky
This work is specialized to stress-strain deformation analysis of dental implant. Failures of osseointegrated implants have been associated with many factors, such as poor bone quality, lack of initial instability, overloading and fractures of implants and abutment screws. Fracture of these elements may be related with a poor fit of the framework, which leads to material fatigue, occlusal overload and intrinsic material failures. The purpose of this study was to analyze the influence of implant diameterand length on stress distribution and to analyze overload risk of clinically evidenced crestal bone loss at the implant neck in mandibular molar periimplant region. Stress-based performances of 4 implants (2 Nobel Biocare, Brĺnemark, and metric implant)were analyzed by linearly elastic 3-dimensional finite element simulations, under a static load. The masticatory load was simulated using an average masticatory force in a natural direction, oblique to the occlusal plane.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of extended abstrakt
ISBN
978-80-7043-824-4
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
—
Název nakladatele
Západočeská unoverzita
Místo vydání
Plzeň 2009
Místo konání akce
Hrad Nečtiny
Datum konání akce
9. 11. 2009
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—