Applications of selected NDT procedures for more detailed identification of crack initiation stage at fatigue tests of aluminium alloys
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F09%3APU84763" target="_blank" >RIV/00216305:26210/09:PU84763 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Applications of selected NDT procedures for more detailed identification of crack initiation stage at fatigue tests of aluminium alloys
Popis výsledku v původním jazyce
The paper describes some basic results of AlMg alloy (EN-AW-6082) behaviour change during high cycle fatigue loading which were detected using AE method and analysis of load frequency changes of the electromagnetic loading device. These procedures allowbasic identification of different stages of fatigue process. The main attention is targeted on more exact identification of the first stage of fatigue cracks propagation. AE signal plots obtained with use of the newly developed AE analyser device calledDAKEL IPL are commented in detail. This apparatus allows for continual recording and processing of data from the acoustic emission sensors. Compared to the up to date commonly used AE analyser devices, the major advantage of this type of analyser is thatit is capable of continually sampling and storing the whole AE signal for as long as there is space to store it.
Název v anglickém jazyce
Applications of selected NDT procedures for more detailed identification of crack initiation stage at fatigue tests of aluminium alloys
Popis výsledku anglicky
The paper describes some basic results of AlMg alloy (EN-AW-6082) behaviour change during high cycle fatigue loading which were detected using AE method and analysis of load frequency changes of the electromagnetic loading device. These procedures allowbasic identification of different stages of fatigue process. The main attention is targeted on more exact identification of the first stage of fatigue cracks propagation. AE signal plots obtained with use of the newly developed AE analyser device calledDAKEL IPL are commented in detail. This apparatus allows for continual recording and processing of data from the acoustic emission sensors. Compared to the up to date commonly used AE analyser devices, the major advantage of this type of analyser is thatit is capable of continually sampling and storing the whole AE signal for as long as there is space to store it.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JL - Únava materiálu a lomová mechanika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F07%2F0508" target="_blank" >GA106/07/0508: Detekce a výzkum rozvoje cyklického poškození moderních AlMg slitin s aplikací vybraných defektoskopických postupů.</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Fatigue design 2009
ISBN
978-2-85400-908-8
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
—
Název nakladatele
CETIM Senlis
Místo vydání
Senlis, Francie
Místo konání akce
Senlis
Datum konání akce
25. 11. 2009
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—