Stress corrosion of partially immersed heat exchanger u-tubes
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F10%3APU87932" target="_blank" >RIV/00216305:26210/10:PU87932 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Stress corrosion of partially immersed heat exchanger u-tubes
Popis výsledku v původním jazyce
In general, every heat exchanger is designed individually. Various aspects, such as inlet and outlet temperatures, flow rates and stream pressures are considered in design process. Pursuit of optimal reliable design, tailored to specific needs is necessary for manufacturers in order to keep up with competition. However, optimal design can be very sensitive to changes in working conditions. In this paper, stress corrosion cracking of heat exchanger u-tubes as a consequence of decreased medium level in shell space is presented. Object of the study is heat exchanger with u-tubes used in petroleum industry. There is a mixture of gas oil and hydrogen in tube space. This mixture also contains sulphur chloride and ammonia therefore corrosion aided stress cracking presents serious threat. Inlet temperature is 350 C and medium flows at the pressure of 4.27 MPa. Shell space is partially filled with cooling water pressurized to 0.88 MPa, which is turned into steam with outlet temperature up to 20
Název v anglickém jazyce
Stress corrosion of partially immersed heat exchanger u-tubes
Popis výsledku anglicky
In general, every heat exchanger is designed individually. Various aspects, such as inlet and outlet temperatures, flow rates and stream pressures are considered in design process. Pursuit of optimal reliable design, tailored to specific needs is necessary for manufacturers in order to keep up with competition. However, optimal design can be very sensitive to changes in working conditions. In this paper, stress corrosion cracking of heat exchanger u-tubes as a consequence of decreased medium level in shell space is presented. Object of the study is heat exchanger with u-tubes used in petroleum industry. There is a mixture of gas oil and hydrogen in tube space. This mixture also contains sulphur chloride and ammonia therefore corrosion aided stress cracking presents serious threat. Inlet temperature is 350 C and medium flows at the pressure of 4.27 MPa. Shell space is partially filled with cooling water pressurized to 0.88 MPa, which is turned into steam with outlet temperature up to 20
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JQ - Strojní zařízení a nástroje
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/2B08048" target="_blank" >2B08048: Odpady jako suroviny a zdroje energie (Waste as raw material and energy source)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Materials of the 19th International Congress of Chemical and Process Engineering CHISA 2010 and the 7th European Congress of Chemical Engineering ECCE-7
ISBN
978-80-02-02248-0
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
—
Název nakladatele
Process Engineering Publisher
Místo vydání
Praha
Místo konání akce
Praha
Datum konání akce
28. 8. 2010
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—