Multi-layer structure of the artery can have significant effects on the resulting mechanical behaviour of the artery wall. Separation of the artery into individual layers is sometimes performed to identify the layer-specific parameters of constitutive model proposed by Holzapfel (2000). Inspired by this single-layer model, a double-layer model was formulated and used for identification of material parameters from homogenized stress-strain data (of non-separated artery wall). The paper demonstrates thatthe layer-specific parameters of the double-layer constitutive model can be indentified without the need of artery separation. The resulting double-layer model can credibly describe the homogenized stress-strain behaviour of the real artery wall including large-strain stiffening effects attributed to multi-layer nature of the artery.
Název v anglickém jazyce
Material parameter identification of arterial wall layers from homogenized stress-strain data
Popis výsledku anglicky
Multi-layer structure of the artery can have significant effects on the resulting mechanical behaviour of the artery wall. Separation of the artery into individual layers is sometimes performed to identify the layer-specific parameters of constitutive model proposed by Holzapfel (2000). Inspired by this single-layer model, a double-layer model was formulated and used for identification of material parameters from homogenized stress-strain data (of non-separated artery wall). The paper demonstrates thatthe layer-specific parameters of the double-layer constitutive model can be indentified without the need of artery separation. The resulting double-layer model can credibly describe the homogenized stress-strain behaviour of the real artery wall including large-strain stiffening effects attributed to multi-layer nature of the artery.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA106%2F09%2F1732" target="_blank" >GA106/09/1732: VÍCEÚROVŇOVÉ MODELOVÁNÍ CHOVÁNÍ HYPERELASTICKÝCH ANIZOTROPNÍCH MATERIÁLŮ</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING
ISSN
1025-5842
e-ISSN
—
Svazek periodika
14
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
33-41
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—