Popis výsledku v původním jazyce
Nowadays, still more often seeks to achieve total quality environment in which we live and work. Among the parameters which to be monitored and controlled also ranks thermal comfort. Thermal comfort means a feeling of satisfaction with the thermal stateof the human environment. If correctly optimize the thermal comfort parameters, will increase human satisfaction with thermal environment, improve his concentration on work and also achieve lower energy costs. Mean radiation temperature and operative temperature, which deals this article with in detail, very clearly tell us about the state of thermal comfort. Since none measurement is absolutely accuracy in our workplace were designed and implemented also two chambers - test and calibration, allowing eliminate a number of negative environmental influences at verification of sensors of these two parameters of thermal comfort.
Název v anglickém jazyce
Thermal comfort and measurement of mean radiant temperature
Popis výsledku anglicky
Nowadays, still more often seeks to achieve total quality environment in which we live and work. Among the parameters which to be monitored and controlled also ranks thermal comfort. Thermal comfort means a feeling of satisfaction with the thermal stateof the human environment. If correctly optimize the thermal comfort parameters, will increase human satisfaction with thermal environment, improve his concentration on work and also achieve lower energy costs. Mean radiation temperature and operative temperature, which deals this article with in detail, very clearly tell us about the state of thermal comfort. Since none measurement is absolutely accuracy in our workplace were designed and implemented also two chambers - test and calibration, allowing eliminate a number of negative environmental influences at verification of sensors of these two parameters of thermal comfort.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JS - Řízení spolehlivosti a kvality, zkušebnictví
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD101%2F09%2FH050" target="_blank" >GD101/09/H050: Výzkum energeticky úsporných zařízení pro dosažení pohody vnitřního prostředí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník přéspěvků Mezinárodní Masarykovy konference pro doktorandy a mladé vědecké pracovníky 2012
ISBN
978-80-905243-3-0
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
2901-2908
Název nakladatele
Magnanimitas
Místo vydání
Hradec Králové
Místo konání akce
Hradec Králové
Datum konání akce
10. 12. 2012
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—