Heat Recovery in Professional Laundry Care Process
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F12%3APU99463" target="_blank" >RIV/00216305:26210/12:PU99463 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Heat Recovery in Professional Laundry Care Process
Popis výsledku v původním jazyce
This paper tackles various specific issues related to professional laundry care process. Design of efficient system of heat recovery in professional laundry is conditioned by successful management of these specifics. The paper also gives several suggestions for the design. Measurement method including original software for data processing was designed for more efficient acquisition of humid air parameters in outlet stream from drying equipment (i.e. dryer, ironer, tunnel finisher). These parameters are relevant for determination of the amount of applicable waste heat and its time course. This method has minimum impact upon equipment operation and its technical readiness to measure and is thus suitable for irregular measurements in laundry facilities. The paper also presents case study of heat exchanger design for heat recovery based on requirements from real laundry operations. Plate-type air-air heat exchanger preheats drying air for tumble dryers while using waste heat from tunnel finisher.
Název v anglickém jazyce
Heat Recovery in Professional Laundry Care Process
Popis výsledku anglicky
This paper tackles various specific issues related to professional laundry care process. Design of efficient system of heat recovery in professional laundry is conditioned by successful management of these specifics. The paper also gives several suggestions for the design. Measurement method including original software for data processing was designed for more efficient acquisition of humid air parameters in outlet stream from drying equipment (i.e. dryer, ironer, tunnel finisher). These parameters are relevant for determination of the amount of applicable waste heat and its time course. This method has minimum impact upon equipment operation and its technical readiness to measure and is thus suitable for irregular measurements in laundry facilities. The paper also presents case study of heat exchanger design for heat recovery based on requirements from real laundry operations. Plate-type air-air heat exchanger preheats drying air for tumble dryers while using waste heat from tunnel finisher.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JP - Průmyslové procesy a zpracování
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0002%2F01%2F01" target="_blank" >ED0002/01/01: NETME Centre (Nové technologie pro strojírenství)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Engineering Transactions
ISSN
1974-9791
e-ISSN
—
Svazek periodika
29
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
6
Strana od-do
391-396
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—