Experimental Investigation on Spray Characteristics of Pressure-Swirl Atomizers for a Small-Sized Jet Engine
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F12%3APU99700" target="_blank" >RIV/00216305:26210/12:PU99700 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental Investigation on Spray Characteristics of Pressure-Swirl Atomizers for a Small-Sized Jet Engine
Popis výsledku v původním jazyce
This study investigated characteristics of sprays generated with two geometrically different pressure-swirl atom-izers for a small-sized aviation turbine engine using Particle Image Velocimetry (PIV) and Phase-Doppler Particle Analyzer (P/DPA) on a coldtest bench. The former nozzle is a spill-return type; the latter one is the intended upgrade in the form of a simplex nozzle. Single-camera and stereoscopic PIV measurements yield distribution of mean velocity and turbulence measured in an axial cross section of the spray cone. P/DPA measurements yield drop-size distribution and axial velocity data. Performed measurements revealed significant differences in spray characteristics of the measured nozzles investigated in the same operating regimes on a cold test bench. These differences are discussed in detail. Analysis of the differences between the two nozzles elucidates the possible impact of the nozzle replacement on the combustion process. This study provides an extensive database for
Název v anglickém jazyce
Experimental Investigation on Spray Characteristics of Pressure-Swirl Atomizers for a Small-Sized Jet Engine
Popis výsledku anglicky
This study investigated characteristics of sprays generated with two geometrically different pressure-swirl atom-izers for a small-sized aviation turbine engine using Particle Image Velocimetry (PIV) and Phase-Doppler Particle Analyzer (P/DPA) on a coldtest bench. The former nozzle is a spill-return type; the latter one is the intended upgrade in the form of a simplex nozzle. Single-camera and stereoscopic PIV measurements yield distribution of mean velocity and turbulence measured in an axial cross section of the spray cone. P/DPA measurements yield drop-size distribution and axial velocity data. Performed measurements revealed significant differences in spray characteristics of the measured nozzles investigated in the same operating regimes on a cold test bench. These differences are discussed in detail. Analysis of the differences between the two nozzles elucidates the possible impact of the nozzle replacement on the combustion process. This study provides an extensive database for
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2012
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
proceedings of 12th International Conference on Liquid Atomization and Spray Systems
ISBN
978-88-903712-1-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
1-8
Název nakladatele
Heidelberg University
Místo vydání
Heidelberg, Germany
Místo konání akce
Heidelberg
Datum konání akce
2. 9. 2012
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—