Computational Modeling of Interaction of Dental Implant with Mandible
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F13%3APU100399" target="_blank" >RIV/00216305:26210/13:PU100399 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computational Modeling of Interaction of Dental Implant with Mandible
Popis výsledku v původním jazyce
This paper is focused on computational modeling of an interaction of dental implant with mandible bone. It describes creation of computational model including model of geometry, materials, loads and constraints. There is a comparative stress-strain analysis of the levels of cancellous bone model. Computations are performed with the use of finite element method. Results show differences between the model which includes trabecular architecture of cancellous bone tissue and the model with non-trabecular cancellous bone tissue. For better description of the processes in bone tissue and at the interface between bone tissue and implant, it is necessary to create the computational model on the highest possible level, i.e. with the trabecular bone tissue.
Název v anglickém jazyce
Computational Modeling of Interaction of Dental Implant with Mandible
Popis výsledku anglicky
This paper is focused on computational modeling of an interaction of dental implant with mandible bone. It describes creation of computational model including model of geometry, materials, loads and constraints. There is a comparative stress-strain analysis of the levels of cancellous bone model. Computations are performed with the use of finite element method. Results show differences between the model which includes trabecular architecture of cancellous bone tissue and the model with non-trabecular cancellous bone tissue. For better description of the processes in bone tissue and at the interface between bone tissue and implant, it is necessary to create the computational model on the highest possible level, i.e. with the trabecular bone tissue.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Mechanics and Materials
ISSN
1660-9336
e-ISSN
—
Svazek periodika
245
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
6
Strana od-do
57-62