Sensorless detection of DC motor rotation direction for automotive fuel pump fault diagnosis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F13%3APU102960" target="_blank" >RIV/00216305:26210/13:PU102960 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Sensorless detection of DC motor rotation direction for automotive fuel pump fault diagnosis
Popis výsledku v původním jazyce
Abstract: - This paper deals with the fault diagnosis of a brushed DC motor used as a pump in an automotive fuel module. The jamming, direction of the rotation and the angular velocity are indirectly measured without access to the rotor. Two implemented approaches are presented. The first method uses the FFT analysis of the measured current for the estimation of angular velocity together with the load of the pump using suction. The developed test lasts min. 6 sec. and reliably detects the direction of the rotation. The second method uses a magnetic field sensor for the detection of the rotation direction. Although it provides a simpler setup and a shorter measurement time, it is also more sensitive to noise and the precise positioning of the sensor.
Název v anglickém jazyce
Sensorless detection of DC motor rotation direction for automotive fuel pump fault diagnosis
Popis výsledku anglicky
Abstract: - This paper deals with the fault diagnosis of a brushed DC motor used as a pump in an automotive fuel module. The jamming, direction of the rotation and the angular velocity are indirectly measured without access to the rotor. Two implemented approaches are presented. The first method uses the FFT analysis of the measured current for the estimation of angular velocity together with the load of the pump using suction. The developed test lasts min. 6 sec. and reliably detects the direction of the rotation. The second method uses a magnetic field sensor for the detection of the rotation direction. Although it provides a simpler setup and a shorter measurement time, it is also more sensitive to noise and the precise positioning of the sensor.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20306 - Audio engineering, reliability analysis
Návaznosti výsledku
Projekt
—
Návaznosti
R - Projekt Ramcoveho programu EK
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Recent Advances in Circuits, Communications and Signal Processing
ISBN
978-1-61804-164-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
195-199
Název nakladatele
WSEAS Press
Místo vydání
Cambridge UK
Místo konání akce
Cambridge
Datum konání akce
20. 2. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—