Off-axis setup taking full advantage of incoherent illumination in coherence-controlled holographic microscope
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F13%3APU103952" target="_blank" >RIV/00216305:26210/13:PU103952 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1364/OE.21.014747" target="_blank" >http://dx.doi.org/10.1364/OE.21.014747</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/OE.21.014747" target="_blank" >10.1364/OE.21.014747</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Off-axis setup taking full advantage of incoherent illumination in coherence-controlled holographic microscope
Popis výsledku v původním jazyce
Coherence-controlled holographic microscope (CCHM) combines off-axis holography and an achromatic grating interferometer allowing for the use of light sources of arbitrary degree of temporal and spatial coherence. This results in coherence gating and strong suppression of coherent noise and parasitic interferences enabling CCHM to reach high phase measurement accuracy and imaging quality. The achievable lateral resolution reaches performance of conventional widefield microscopes, which allows resolvingup to twice smaller details when compared to typical off-axis setups. Imaging characteristics can be controlled arbitrarily by coherence between two extremes: fully coherent holography and confocal-like incoherent holography. The basic setup parameters are derived and described in detail and experimental validations of imaging characteristics are demonstrated.
Název v anglickém jazyce
Off-axis setup taking full advantage of incoherent illumination in coherence-controlled holographic microscope
Popis výsledku anglicky
Coherence-controlled holographic microscope (CCHM) combines off-axis holography and an achromatic grating interferometer allowing for the use of light sources of arbitrary degree of temporal and spatial coherence. This results in coherence gating and strong suppression of coherent noise and parasitic interferences enabling CCHM to reach high phase measurement accuracy and imaging quality. The achievable lateral resolution reaches performance of conventional widefield microscopes, which allows resolvingup to twice smaller details when compared to typical off-axis setups. Imaging characteristics can be controlled arbitrarily by coherence between two extremes: fully coherent holography and confocal-like incoherent holography. The basic setup parameters are derived and described in detail and experimental validations of imaging characteristics are demonstrated.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
OPTICS EXPRESS
ISSN
1094-4087
e-ISSN
—
Svazek periodika
21
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
16
Strana od-do
14747-14762
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—