Steel oxidation during the hot rolling in-line process is undesirable behavior. High pressure descaling nozzles are often used to remove oxides from the surface of a product. The water spray from high pressure nozzles also causes intense cooling. Knowledge of this cooling intensity is necessary for on-line simulations used by control systems. Knowledge of boundary conditions can also help with the choice of descaling nozzles. These boundary conditions are surface temperature, surface heat flux and the heat transfer coefficient (HTC). The HTC can be obtained from the measured temperature histories inside a test plate by inverse heat conduction problem or from the measured surface temperatures. This article describes a new inverse method for the computation of HTCs from surface temperature measurements using an infrared line-scanner during descaling experiments. The measurement technique used to obtain data for the inverse method is described as well. Data from real measurements are presented and evaluated.
Název v anglickém jazyce
Computing Cooling Intensity from Descaling Experiments
Popis výsledku anglicky
Steel oxidation during the hot rolling in-line process is undesirable behavior. High pressure descaling nozzles are often used to remove oxides from the surface of a product. The water spray from high pressure nozzles also causes intense cooling. Knowledge of this cooling intensity is necessary for on-line simulations used by control systems. Knowledge of boundary conditions can also help with the choice of descaling nozzles. These boundary conditions are surface temperature, surface heat flux and the heat transfer coefficient (HTC). The HTC can be obtained from the measured temperature histories inside a test plate by inverse heat conduction problem or from the measured surface temperatures. This article describes a new inverse method for the computation of HTCs from surface temperature measurements using an infrared line-scanner during descaling experiments. The measurement technique used to obtain data for the inverse method is described as well. Data from real measurements are presented and evaluated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JG - Hutnictví, kovové materiály
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Steelsim 2013
ISBN
978-80-260-3912-9
ISSN
—
e-ISSN
—
Počet stran výsledku
8
Strana od-do
19-19
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Ostrava
Datum konání akce
10. 9. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—