Investigation of Flow in a Model of Human Airways using Constant Temperature Anemometry and Numerical Simulation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F13%3APU106769" target="_blank" >RIV/00216305:26210/13:PU106769 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Investigation of Flow in a Model of Human Airways using Constant Temperature Anemometry and Numerical Simulation
Popis výsledku v původním jazyce
Mechanics of flow in human lungs has major influence on a transport and deposition of inhaled particles. A semi-realistic model of human tracheobronchial airways was used for experimental measurement and numerical simulation of an air velocity field. Axial velocities in 14 points in a trachea were measured using Constant Temperature Anemometry and compared with numerical simulation. The influence of a computational mesh quality was investigated as well. The experimental and simulated results proved significant differences between the methods. Probable causes of the discrepancies are a size of the anemometric probe, accuracy of the numerical method and its sensitivity to mesh quality and boundary conditions.
Název v anglickém jazyce
Investigation of Flow in a Model of Human Airways using Constant Temperature Anemometry and Numerical Simulation
Popis výsledku anglicky
Mechanics of flow in human lungs has major influence on a transport and deposition of inhaled particles. A semi-realistic model of human tracheobronchial airways was used for experimental measurement and numerical simulation of an air velocity field. Axial velocities in 14 points in a trachea were measured using Constant Temperature Anemometry and compared with numerical simulation. The influence of a computational mesh quality was investigated as well. The experimental and simulated results proved significant differences between the methods. Probable causes of the discrepancies are a size of the anemometric probe, accuracy of the numerical method and its sensitivity to mesh quality and boundary conditions.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Recent Advances in Fluid Mechanics and Heat & Mass Transfer
ISBN
978-1-61804-183-8
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
35-40
Název nakladatele
WSEAS Press
Místo vydání
Vouliagmeni, Athens, Greece
Místo konání akce
Vouliagmeni, Athens
Datum konání akce
14. 5. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—