Finite element analysis of bone loss around failing implants
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU108964" target="_blank" >RIV/00216305:26210/14:PU108964 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.sciencedirect.com/science/article/pii/S0261306914003550" target="_blank" >http://www.sciencedirect.com/science/article/pii/S0261306914003550</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.matdes.2014.04.080" target="_blank" >10.1016/j.matdes.2014.04.080</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Finite element analysis of bone loss around failing implants
Popis výsledku v původním jazyce
Dental implants induce diverse forces on their surrounding bone. However, when excessive unphysiological forces are applied, resorption of the neighbouring bone may occur. The aim of this study was to assess possible causes of bone loss around failing dental implants using finite element analysis. A further aim was to assess the implications of progressive bone loss on the strains induced by dental implants. Between 2003 and 2009 a total of 3700 implant operations were performed in a private clinic. Ten patients had 16 fixtures which developed severe marginal bone defects. Finite element analysis was used to assess the effective strains produced at the bone-implant interface under unidirectional axial loading. These simulations were carried out on 4 specific implant types – Camlog Plus, Astra Osseo Speed, Straumann BL and Straumann S/SP. All implant types displayed degraded performance under circular and horizontal bone loss conditions. This is evidenced by increased distribution of pathological strain intensities (>3000 micro-strain), in accordance with the mechanostat hypothesis, in the surrounding bone. Among the implants, the Camlog design seemed to have performed poorly, especially at the chamfer in the implant collar (>25000 micro-strain).Implants are designed to perform under nearly ideal conditions from insertion till osseointegration. However, when the surrounding bone undergoes remodelling, implant geometries can have varied performance, which in some cases can exacerbate bone loss. The results of this study indicate the importance of evaluating implant geometries under clinically observed conditions of progressive bone loss.
Název v anglickém jazyce
Finite element analysis of bone loss around failing implants
Popis výsledku anglicky
Dental implants induce diverse forces on their surrounding bone. However, when excessive unphysiological forces are applied, resorption of the neighbouring bone may occur. The aim of this study was to assess possible causes of bone loss around failing dental implants using finite element analysis. A further aim was to assess the implications of progressive bone loss on the strains induced by dental implants. Between 2003 and 2009 a total of 3700 implant operations were performed in a private clinic. Ten patients had 16 fixtures which developed severe marginal bone defects. Finite element analysis was used to assess the effective strains produced at the bone-implant interface under unidirectional axial loading. These simulations were carried out on 4 specific implant types – Camlog Plus, Astra Osseo Speed, Straumann BL and Straumann S/SP. All implant types displayed degraded performance under circular and horizontal bone loss conditions. This is evidenced by increased distribution of pathological strain intensities (>3000 micro-strain), in accordance with the mechanostat hypothesis, in the surrounding bone. Among the implants, the Camlog design seemed to have performed poorly, especially at the chamfer in the implant collar (>25000 micro-strain).Implants are designed to perform under nearly ideal conditions from insertion till osseointegration. However, when the surrounding bone undergoes remodelling, implant geometries can have varied performance, which in some cases can exacerbate bone loss. The results of this study indicate the importance of evaluating implant geometries under clinically observed conditions of progressive bone loss.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10610 - Biophysics
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Materials and design
ISSN
0261-3069
e-ISSN
—
Svazek periodika
61
Číslo periodika v rámci svazku
22
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
177-184
Kód UT WoS článku
000337854100022
EID výsledku v databázi Scopus
2-s2.0-84900803213