Biomechanical testing of spinal segment fixed by ArcoFix system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU109836" target="_blank" >RIV/00216305:26210/14:PU109836 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biomechanical testing of spinal segment fixed by ArcoFix system
Popis výsledku v původním jazyce
The aim of this study was to compare the mechanical properties of the spinal segment in the intact state, destabilized (injury) state and the state after fixation by implant ArcoFix. The problem was solved by using the experimental modelling ZWICK testing machine. The study was based on in vitro biomechanical testing. Ten test samples were prepared for the experiment. Mechanical properties were described by the value of force couple needed to twist the specimen during the applied tensile force. Statistical analysis of measured results confirmed the hypothesis of different behavior of the states of intact, injured and fixed samples. Analysis did not confirm different mechanical behavior of intact and fixated specimens when comparing by the couple moment.
Název v anglickém jazyce
Biomechanical testing of spinal segment fixed by ArcoFix system
Popis výsledku anglicky
The aim of this study was to compare the mechanical properties of the spinal segment in the intact state, destabilized (injury) state and the state after fixation by implant ArcoFix. The problem was solved by using the experimental modelling ZWICK testing machine. The study was based on in vitro biomechanical testing. Ten test samples were prepared for the experiment. Mechanical properties were described by the value of force couple needed to twist the specimen during the applied tensile force. Statistical analysis of measured results confirmed the hypothesis of different behavior of the states of intact, injured and fixed samples. Analysis did not confirm different mechanical behavior of intact and fixated specimens when comparing by the couple moment.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BO - Biofyzika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ENGINEERING MECHANICS 2014
ISBN
978-80-214-4871-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
424-427
Název nakladatele
BUT
Místo vydání
Brno
Místo konání akce
Svratka
Datum konání akce
12. 5. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—