The determination of field usability of method measuring temperature fields in the air using an infrared camera
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU110265" target="_blank" >RIV/00216305:26210/14:PU110265 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1051/epjconf/20146702091" target="_blank" >http://dx.doi.org/10.1051/epjconf/20146702091</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/20146702091" target="_blank" >10.1051/epjconf/20146702091</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The determination of field usability of method measuring temperature fields in the air using an infrared camera
Popis výsledku v původním jazyce
The article deals with the field usability determination of the method for measuring temperature fields in the air using an infrared camera. This method is based on the visualization of temperature fields on an auxiliary material, which is inserted intothe non-isothermal air flow. In this article the field usability is determined from time constants of this method, which define borders of usability for low temperature differences (between air flow temperature and surrounding temperature) and for low air flow velocities. The field usability determination for measuring temperature fields in the air can be used in many various applications such as air-heating and air-conditioning where the method of measuring temperature fields in the air by infrared camera can be used.
Název v anglickém jazyce
The determination of field usability of method measuring temperature fields in the air using an infrared camera
Popis výsledku anglicky
The article deals with the field usability determination of the method for measuring temperature fields in the air using an infrared camera. This method is based on the visualization of temperature fields on an auxiliary material, which is inserted intothe non-isothermal air flow. In this article the field usability is determined from time constants of this method, which define borders of usability for low temperature differences (between air flow temperature and surrounding temperature) and for low air flow velocities. The field usability determination for measuring temperature fields in the air can be used in many various applications such as air-heating and air-conditioning where the method of measuring temperature fields in the air by infrared camera can be used.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
BJ - Termodynamika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/ED0002%2F01%2F01" target="_blank" >ED0002/01/01: NETME Centre (Nové technologie pro strojírenství)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
EPJ Web of Conferences
ISSN
2100-014X
e-ISSN
—
Svazek periodika
2014
Číslo periodika v rámci svazku
67
Stát vydavatele periodika
FR - Francouzská republika
Počet stran výsledku
4
Strana od-do
1-4