CFD and FEA Boiler Collector Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU110508" target="_blank" >RIV/00216305:26210/14:PU110508 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3303/CET1439142" target="_blank" >http://dx.doi.org/10.3303/CET1439142</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3303/CET1439142" target="_blank" >10.3303/CET1439142</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CFD and FEA Boiler Collector Analysis
Popis výsledku v původním jazyce
This article presents a troubleshooting analysis of a steam boiler which serves for steam overheating. Operating of this boiler is accompanied by unexpected difficulties – repetitive crack occurring on a boilers collector (Figure 1). Therefore, the substantial part of this paper is focused on identifying of the main reason of damaging. The first step in damage identification was static, respective quasi-static FEM (finite element method) analyses. These analyses did not confirm the cause of damaging. Therefore, it was approached to analytical calculations (thermal – hydraulic and vibration calculations) which were used for additional boundary conditions estimation. The vibration analytical analyses predicted vortex excitation. The occurrence of vortex excitation behind the tube (Figure 6) was subsequently confirmed by CFD (computational fluid dynamics) and FSI (fluid structure interaction) analyses. These analyses revealed the cause of tube bundle damaging, which was fluid induced vibration. Significant part of this article is devoted to discussion about used computational models, boundary conditions and results of analyses. The last part of this article is targeted at proposing corrective action.
Název v anglickém jazyce
CFD and FEA Boiler Collector Analysis
Popis výsledku anglicky
This article presents a troubleshooting analysis of a steam boiler which serves for steam overheating. Operating of this boiler is accompanied by unexpected difficulties – repetitive crack occurring on a boilers collector (Figure 1). Therefore, the substantial part of this paper is focused on identifying of the main reason of damaging. The first step in damage identification was static, respective quasi-static FEM (finite element method) analyses. These analyses did not confirm the cause of damaging. Therefore, it was approached to analytical calculations (thermal – hydraulic and vibration calculations) which were used for additional boundary conditions estimation. The vibration analytical analyses predicted vortex excitation. The occurrence of vortex excitation behind the tube (Figure 6) was subsequently confirmed by CFD (computational fluid dynamics) and FSI (fluid structure interaction) analyses. These analyses revealed the cause of tube bundle damaging, which was fluid induced vibration. Significant part of this article is devoted to discussion about used computational models, boundary conditions and results of analyses. The last part of this article is targeted at proposing corrective action.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20401 - Chemical engineering (plants, products)
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 17th Conference on Process Integration, Modelling and Optimisation for Energy Saving and Pollution Reduction PRES 2014
ISBN
978-88-95608-30-3
ISSN
2283-9216
e-ISSN
—
Počet stran výsledku
6
Strana od-do
847-852
Název nakladatele
Aidic Servizi S.r.l.
Místo vydání
Milan, Italy
Místo konání akce
Prague
Datum konání akce
23. 8. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000346757600142