Three-dimensional optical assessment of experimental iatrogenic mechanical damage to canine dental enamel caused by a sonic scaler
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F14%3APU112161" target="_blank" >RIV/00216305:26210/14:PU112161 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62157124:16170/14:43872761
Výsledek na webu
<a href="http://vri.cz/docs/vetmed/59-6-293.pdf" target="_blank" >http://vri.cz/docs/vetmed/59-6-293.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Three-dimensional optical assessment of experimental iatrogenic mechanical damage to canine dental enamel caused by a sonic scaler
Popis výsledku v původním jazyce
Removal of dental calculus deposits is one of the basic parts of professional dental cleaning. Despite the popularity of power-driven scalers, several risks are associated with their use, mechanical damage of the enamel surface being one of the most important. The present study evaluated enamel damage caused by a sonic scaler in different work patterns to quantify the damage and allow a clear comparison. Seventy-five canine teeth were carefully extracted from twenty-three dogs. The scaler was used on aclean surface with several combinations of time (five to twenty seconds) and parts of the scaler (point vs. side of the tip). Subsequently, damaged surface topography was mapped using three-dimensional optical microscopy. The results revealed a high variance in defect depth which was influenced by both factors. Statistical assessment confirmed highly significant (P < 0.001) or at least significant (P < 0.05) differences in data acquired for each group. As expected, the shallowest defects
Název v anglickém jazyce
Three-dimensional optical assessment of experimental iatrogenic mechanical damage to canine dental enamel caused by a sonic scaler
Popis výsledku anglicky
Removal of dental calculus deposits is one of the basic parts of professional dental cleaning. Despite the popularity of power-driven scalers, several risks are associated with their use, mechanical damage of the enamel surface being one of the most important. The present study evaluated enamel damage caused by a sonic scaler in different work patterns to quantify the damage and allow a clear comparison. Seventy-five canine teeth were carefully extracted from twenty-three dogs. The scaler was used on aclean surface with several combinations of time (five to twenty seconds) and parts of the scaler (point vs. side of the tip). Subsequently, damaged surface topography was mapped using three-dimensional optical microscopy. The results revealed a high variance in defect depth which was influenced by both factors. Statistical assessment confirmed highly significant (P < 0.001) or at least significant (P < 0.05) differences in data acquired for each group. As expected, the shallowest defects
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
GJ - Choroby a škůdci zvířat, veterinární medicina
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Veterinární medicína
ISSN
0375-8427
e-ISSN
—
Svazek periodika
59
Číslo periodika v rámci svazku
6
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
6
Strana od-do
293-298
Kód UT WoS článku
000342070600004
EID výsledku v databázi Scopus
—