Fatigue Testing of Polymeric Hollow Fibre Heat Transfer Surfaces by Pulsating Pressure Loads
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F15%3APU114139" target="_blank" >RIV/00216305:26210/15:PU114139 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.engmech.cz/im/im/" target="_blank" >http://www.engmech.cz/im/im/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Fatigue Testing of Polymeric Hollow Fibre Heat Transfer Surfaces by Pulsating Pressure Loads
Popis výsledku v původním jazyce
This article deals with the fatigue tests of polymeric hollow fibre heat transfer surfaces. Hollow fibres have an outer diameter around 0.5-0.8 mm and a thickness of the wall is 10 % of the outer diameter. These heat transfer surfaces made from plasticshave some limitations but also a lot of benefits. One of the limitations is durability of plastic under fatigue loading. The heat transfer surfaces were subjected to pulsating pressure loads under different conditions (level of pressure, ambient temperature, number of cycles). Firstly, just the pulsating load was applied and the behaviour of hollow fibres was observed paying special attention to the presence of a leaking, rupture, etc. Then some other conditions of operations were added. The heat transfer surfaces were immersed in a hot bath and loaded by pulsating pressure and high temperature simultaneously. Testing under the different temperature is important because the temperature significantly affects the material properties. The
Název v anglickém jazyce
Fatigue Testing of Polymeric Hollow Fibre Heat Transfer Surfaces by Pulsating Pressure Loads
Popis výsledku anglicky
This article deals with the fatigue tests of polymeric hollow fibre heat transfer surfaces. Hollow fibres have an outer diameter around 0.5-0.8 mm and a thickness of the wall is 10 % of the outer diameter. These heat transfer surfaces made from plasticshave some limitations but also a lot of benefits. One of the limitations is durability of plastic under fatigue loading. The heat transfer surfaces were subjected to pulsating pressure loads under different conditions (level of pressure, ambient temperature, number of cycles). Firstly, just the pulsating load was applied and the behaviour of hollow fibres was observed paying special attention to the presence of a leaking, rupture, etc. Then some other conditions of operations were added. The heat transfer surfaces were immersed in a hot bath and loaded by pulsating pressure and high temperature simultaneously. Testing under the different temperature is important because the temperature significantly affects the material properties. The
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
ENGINEERING MECHANICS 2015 21st International Conference Engineering Mechanics 2015
ISBN
978-80-86246-42-0
ISSN
—
e-ISSN
—
Počet stran výsledku
2
Strana od-do
30-31
Název nakladatele
Institute of Theoretical and Applied Mechanics
Místo vydání
Svratka
Místo konání akce
Svratka
Datum konání akce
11. 5. 2015
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—