Popis výsledku v původním jazyce
Fired heaters are used all over the World for refinery processes. Many of them are designed according the American Petroleum Institute Standard 560. Several facilities encounter significant deformation of tubes or other imperfection related to the tube wall heat load. This leads us to investigation of design parameters suggested by the API standard 560. The key design parameters are related to non-uniformity factors, which represent wall heat flux profile over the length and circumference of tube. Sincethe onsite investigation is almost impossible the numerical flow simulation is used. The present work reports parametric studies of tube deformations in a cylindrical fired heater (radially and tangentially deformed tubes). The results are reported in the form used by furnace designers, i.e. in terms of circumferential and longitudinal heat flux factor. This way, the work provides information on the effect that deformations of tubes during the lifetime of a furnace may have on heat flux
Název v anglickém jazyce
Fired heaters: validation of design parameters based on numerical modelling
Popis výsledku anglicky
Fired heaters are used all over the World for refinery processes. Many of them are designed according the American Petroleum Institute Standard 560. Several facilities encounter significant deformation of tubes or other imperfection related to the tube wall heat load. This leads us to investigation of design parameters suggested by the API standard 560. The key design parameters are related to non-uniformity factors, which represent wall heat flux profile over the length and circumference of tube. Sincethe onsite investigation is almost impossible the numerical flow simulation is used. The present work reports parametric studies of tube deformations in a cylindrical fired heater (radially and tangentially deformed tubes). The results are reported in the form used by furnace designers, i.e. in terms of circumferential and longitudinal heat flux factor. This way, the work provides information on the effect that deformations of tubes during the lifetime of a furnace may have on heat flux
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BK - Mechanika tekutin
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
10th European Conference on Industrial Furnaces and Boilers
ISBN
978-972-99309-7-3
ISSN
—
e-ISSN
—
Počet stran výsledku
12
Strana od-do
1-12
Název nakladatele
CENERTEC
Místo vydání
Rio Tinto, Portugal
Místo konání akce
Porto
Datum konání akce
7. 4. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—