In Situ Observation of Lubricant Film within Artificial Hip Joints
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F15%3APU116220" target="_blank" >RIV/00216305:26210/15:PU116220 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
In Situ Observation of Lubricant Film within Artificial Hip Joints
Popis výsledku v původním jazyce
The aim of this study is to clarify the interfacial lubrication processes within artificial hip joints. For this purpose, pendulum hip joint simulator in combination with thin film colorimetric interferometry was employed. The experimental device allowsto study friction and lubrication of artificial hip joints with respect to real geometry of rubbing surfaces including diameteral clearance. The contact of metal femoral head and glass acetabular cup was observed using an optical test rig, while the chromatic interferograms of contact region were captured via high-speed CMOS camera. The contact was lubricated by 25% bovine serum solution. All the measurements were conducted under body temperature of 37 °C. To investigate the influence of kinematic conditions, two different types of motions were applied. Firstly, the pendulum deflected at an initial offset angle was allowed to oscillate freely in the flexion-extension plane, while the motion was damped naturally. Under these transient co
Název v anglickém jazyce
In Situ Observation of Lubricant Film within Artificial Hip Joints
Popis výsledku anglicky
The aim of this study is to clarify the interfacial lubrication processes within artificial hip joints. For this purpose, pendulum hip joint simulator in combination with thin film colorimetric interferometry was employed. The experimental device allowsto study friction and lubrication of artificial hip joints with respect to real geometry of rubbing surfaces including diameteral clearance. The contact of metal femoral head and glass acetabular cup was observed using an optical test rig, while the chromatic interferograms of contact region were captured via high-speed CMOS camera. The contact was lubricated by 25% bovine serum solution. All the measurements were conducted under body temperature of 37 °C. To investigate the influence of kinematic conditions, two different types of motions were applied. Firstly, the pendulum deflected at an initial offset angle was allowed to oscillate freely in the flexion-extension plane, while the motion was damped naturally. Under these transient co
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
JR - Ostatní strojírenství
OECD FORD obor
—
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů