Influence of Underpressure on Heat Transfer And Temperature Field at Sprinkled Tube Bundle
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F16%3APU118130" target="_blank" >RIV/00216305:26210/16:PU118130 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.832.200" target="_blank" >http://dx.doi.org/10.4028/www.scientific.net/AMM.832.200</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.4028/www.scientific.net/AMM.832.200" target="_blank" >10.4028/www.scientific.net/AMM.832.200</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of Underpressure on Heat Transfer And Temperature Field at Sprinkled Tube Bundle
Popis výsledku v původním jazyce
Sprinkled tube bundles with a thin liquid film flowing over them are used in various technology processes where it is necessary to separate the vapour and liquid phases quickly and efficiently at low temperatures with a corresponding decrease of pressure around the tube bundle. In ideal conditions water boils at the whole surface of an exchanger, but in practice it must be considered that in original spots of contact between water and the exchanger wall the water will not boil at the tubes' surface but the cooling liquid will merely be heated-up. The article focuses on these processes. Experiments have been carried out at a tube bundle consisting of copper tubes of 12 mm diameter placed horizontally one above another that have been heated by water of an average input temperature approx. 40 °C. This bundle has been sprinkled by cool water at temperature of 15 °C and pressure has been gradually decreased using an exhauster at constant flow rates of heating and falling film liquid inside an experimental device's chamber. Was tested flow of sprinkled liquid in the range of 4-9 liters per minute, which corresponds to the range of Reynolds numbers of about 300 to 600 [-]. The result of these experiments is a studied heat transfer coefficient at the surface of a sprinkled tube bundle during heating of the cooling liquid with a transition into boiling of the liquid at the bundle. At a flow of 8 liters per minute were acquired sequence thermal camera FLIR SC 660. After evaluation of the sequences were generated maps of the temperature field according to decreasing the pressure and its standard deviation. From the contour graphs can evaluate the thermal stability of the liquid film on the spray tube bundle.
Název v anglickém jazyce
Influence of Underpressure on Heat Transfer And Temperature Field at Sprinkled Tube Bundle
Popis výsledku anglicky
Sprinkled tube bundles with a thin liquid film flowing over them are used in various technology processes where it is necessary to separate the vapour and liquid phases quickly and efficiently at low temperatures with a corresponding decrease of pressure around the tube bundle. In ideal conditions water boils at the whole surface of an exchanger, but in practice it must be considered that in original spots of contact between water and the exchanger wall the water will not boil at the tubes' surface but the cooling liquid will merely be heated-up. The article focuses on these processes. Experiments have been carried out at a tube bundle consisting of copper tubes of 12 mm diameter placed horizontally one above another that have been heated by water of an average input temperature approx. 40 °C. This bundle has been sprinkled by cool water at temperature of 15 °C and pressure has been gradually decreased using an exhauster at constant flow rates of heating and falling film liquid inside an experimental device's chamber. Was tested flow of sprinkled liquid in the range of 4-9 liters per minute, which corresponds to the range of Reynolds numbers of about 300 to 600 [-]. The result of these experiments is a studied heat transfer coefficient at the surface of a sprinkled tube bundle during heating of the cooling liquid with a transition into boiling of the liquid at the bundle. At a flow of 8 liters per minute were acquired sequence thermal camera FLIR SC 660. After evaluation of the sequences were generated maps of the temperature field according to decreasing the pressure and its standard deviation. From the contour graphs can evaluate the thermal stability of the liquid film on the spray tube bundle.
Klasifikace
Druh
J<sub>ost</sub> - Ostatní články v recenzovaných periodicích
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Applied Mechanics and Materials
ISSN
1662-7482
e-ISSN
—
Svazek periodika
neuveden
Číslo periodika v rámci svazku
832
Stát vydavatele periodika
CH - Švýcarská konfederace
Počet stran výsledku
7
Strana od-do
200-206
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—