Root Cause Analysis of Superheater Tubes Failure
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F16%3APU125133" target="_blank" >RIV/00216305:26210/16:PU125133 - isvavai.cz</a>
Výsledek na webu
<a href="http://icmt24.com/e_files/content/Book%20of%20Abstracts.pdf" target="_blank" >http://icmt24.com/e_files/content/Book%20of%20Abstracts.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Root Cause Analysis of Superheater Tubes Failure
Popis výsledku v původním jazyce
Superheater tube failure is listed among major causes of fossil fuel fired boiler outage, therefore, it is necessary not only to identify and repair it in case of failure but also to eliminate the root cause of this problem. As there may be multiple reasons of failure in such exposed equipment as superheater, thorough investigation of more than one probable cause is usually required. This article is focused on failure analysis of the boiler located in the chemical plant. After a leakage was discovered, several cracks on the superheater tubes were identified as its main cause. It was necessary to assess the extent of the damage, to detect the root cause of this damage and to propose corrective actions. Two problematic locations with cracks were identified during the visual inspection; the first at the superheater tube bends and the second in a weld joint between the superheater and a transfer pipe. As a first step, material microstructure and composition analyses of tubes were carried out in those crit
Název v anglickém jazyce
Root Cause Analysis of Superheater Tubes Failure
Popis výsledku anglicky
Superheater tube failure is listed among major causes of fossil fuel fired boiler outage, therefore, it is necessary not only to identify and repair it in case of failure but also to eliminate the root cause of this problem. As there may be multiple reasons of failure in such exposed equipment as superheater, thorough investigation of more than one probable cause is usually required. This article is focused on failure analysis of the boiler located in the chemical plant. After a leakage was discovered, several cracks on the superheater tubes were identified as its main cause. It was necessary to assess the extent of the damage, to detect the root cause of this damage and to propose corrective actions. Two problematic locations with cracks were identified during the visual inspection; the first at the superheater tube bends and the second in a weld joint between the superheater and a transfer pipe. As a first step, material microstructure and composition analyses of tubes were carried out in those crit
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
<a href="/cs/project/TE02000236" target="_blank" >TE02000236: Centrum kompetence pro energetické využití odpadů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů