Experimental investigation of the check valve behaviour when the flow is reversing
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F17%3APU123839" target="_blank" >RIV/00216305:26210/17:PU123839 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.epj-conferences.org/articles/epjconf/abs/2017/12/epjconf_efm2017_02036/epjconf_efm2017_02036.html" target="_blank" >https://www.epj-conferences.org/articles/epjconf/abs/2017/12/epjconf_efm2017_02036/epjconf_efm2017_02036.html</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1051/epjconf/201714302036" target="_blank" >10.1051/epjconf/201714302036</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Experimental investigation of the check valve behaviour when the flow is reversing
Popis výsledku v původním jazyce
Check valve in a pipeline is supposed to prevent the reverse flow and to allow the flow in the positive direction. The construction of check valves follows these requirements, but the check valve must not cause pressure pulsations in transients. It means when the fluid is accelerating or decelerating. The article describes an experimental investigation of a swing check valve when the flow is changing its direction. The check valve was placed in an experimental circuit, where the pressure on the upstream and downstream side of the valve was measured and the current value of flow rate was determined. The goal was to simulate conditions in the real system, where the check valve slam had been observed.
Název v anglickém jazyce
Experimental investigation of the check valve behaviour when the flow is reversing
Popis výsledku anglicky
Check valve in a pipeline is supposed to prevent the reverse flow and to allow the flow in the positive direction. The construction of check valves follows these requirements, but the check valve must not cause pressure pulsations in transients. It means when the fluid is accelerating or decelerating. The article describes an experimental investigation of a swing check valve when the flow is changing its direction. The check valve was placed in an experimental circuit, where the pressure on the upstream and downstream side of the valve was measured and the current value of flow rate was determined. The goal was to simulate conditions in the real system, where the check valve slam had been observed.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
<a href="/cs/project/TH01011352" target="_blank" >TH01011352: Inovativní výzkum zpětných klapek pro extrémní provozní podmínky v energetice</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
EPJ Web of Conferences
ISBN
—
ISSN
2100-014X
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
EDP Sciences
Místo vydání
Neuveden
Místo konání akce
Mariánské lázně
Datum konání akce
15. 11. 2016
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
000407743800038