SECONDARY COOLING OVERLAPPED WITH BEARING HOUSING IN A CONTINUOUS CASTER
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F18%3APU128039" target="_blank" >RIV/00216305:26210/18:PU128039 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
SECONDARY COOLING OVERLAPPED WITH BEARING HOUSING IN A CONTINUOUS CASTER
Popis výsledku v původním jazyce
This article deals with the secondary cooling in a continuous caster. In particular, it deals with homogeneity / inhomogeneity in places where surface of slab is partial shielded by rollers and bearing pocket between rollers. Influence of gap between rollers was also considered. Homogeneity of cooling intensity distribution was experimentally studied in two stages (cold and hot tests). In the first stage (cold tests) water flow and water distribution was observed optically using a transparent board with studied surface structures (rollers and bearing pockets). In the second stage (hot tests) the cooling tests with steel plate (fitted with studied structures) were performed. Cooling homogeneity were studied based on temperature distribution of the non-cooled side of sample, which was recorded by infrared camera.
Název v anglickém jazyce
SECONDARY COOLING OVERLAPPED WITH BEARING HOUSING IN A CONTINUOUS CASTER
Popis výsledku anglicky
This article deals with the secondary cooling in a continuous caster. In particular, it deals with homogeneity / inhomogeneity in places where surface of slab is partial shielded by rollers and bearing pocket between rollers. Influence of gap between rollers was also considered. Homogeneity of cooling intensity distribution was experimentally studied in two stages (cold and hot tests). In the first stage (cold tests) water flow and water distribution was observed optically using a transparent board with studied surface structures (rollers and bearing pockets). In the second stage (hot tests) the cooling tests with steel plate (fitted with studied structures) were performed. Cooling homogeneity were studied based on temperature distribution of the non-cooled side of sample, which was recorded by infrared camera.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1202" target="_blank" >LO1202: NETME CENTRE PLUS</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Sborník konference METAL 2018
ISBN
978-80-87294-83-3
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
Tanger, Ostrava
Místo vydání
Ostrava
Místo konání akce
Brno
Datum konání akce
23. 5. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000461832200008