Development of reciprocating tribometer for testing synovial joint
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F18%3APU128558" target="_blank" >RIV/00216305:26210/18:PU128558 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.engmech.cz/improc/2018/169.pdf" target="_blank" >http://www.engmech.cz/improc/2018/169.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21495/91-8-169" target="_blank" >10.21495/91-8-169</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Development of reciprocating tribometer for testing synovial joint
Popis výsledku v původním jazyce
The painless movement is very important in active life; therefore, the right function of our synovial joints is necessary. The synovial joints can be injured during human life in several ways. When the synovial joint is too damaged, change for the artificial joint follows. The artificial joint does not have long lifetime; therefore, the operation of the damaged joint is usually postponed by medical treatments (viscosuplementation). Scientists have to understand lubrication and wear processes to postpone the operation of the artificial joint. There are too many unanswered questions in this field. However, recently this field of science is becoming very popular and the number of publications is increasing. This article is a presentation of a new tribometer for research in biotribologic field. The new tribometer will allow us to do research on lubrication of the human joint cartilage. We will be able to observe the cartilage-on-glass contact and visualize the lubrication film. We will also be able to measure friction coefficient during the experiments. This conception of tribometer does not exist among conventional suppliers.
Název v anglickém jazyce
Development of reciprocating tribometer for testing synovial joint
Popis výsledku anglicky
The painless movement is very important in active life; therefore, the right function of our synovial joints is necessary. The synovial joints can be injured during human life in several ways. When the synovial joint is too damaged, change for the artificial joint follows. The artificial joint does not have long lifetime; therefore, the operation of the damaged joint is usually postponed by medical treatments (viscosuplementation). Scientists have to understand lubrication and wear processes to postpone the operation of the artificial joint. There are too many unanswered questions in this field. However, recently this field of science is becoming very popular and the number of publications is increasing. This article is a presentation of a new tribometer for research in biotribologic field. The new tribometer will allow us to do research on lubrication of the human joint cartilage. We will be able to observe the cartilage-on-glass contact and visualize the lubrication film. We will also be able to measure friction coefficient during the experiments. This conception of tribometer does not exist among conventional suppliers.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LTAUSA17150" target="_blank" >LTAUSA17150: Vliv tribologických procesů na životnost náhrad kolenního kloubu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Engineering Mechanics 2018
ISBN
978-80-86246-88-8
ISSN
1805-8256
e-ISSN
—
Počet stran výsledku
4
Strana od-do
169-172
Název nakladatele
Institute of Theoretical and Applied Mechanics of the Czech Academy of Sciences, Prague
Místo vydání
Praha
Místo konání akce
Svratka
Datum konání akce
14. 5. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000465489800042