Predictive Simulation-based Optimisation of Cooling System Including a Sprinkler Tank
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F18%3APU130489" target="_blank" >RIV/00216305:26210/18:PU130489 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.3303/CET1870059" target="_blank" >http://dx.doi.org/10.3303/CET1870059</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3303/CET1870059" target="_blank" >10.3303/CET1870059</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Predictive Simulation-based Optimisation of Cooling System Including a Sprinkler Tank
Popis výsledku v původním jazyce
Prerequisite for an efficient cooling energy system is the knowledge and the optimal combination of different operating conditions of individual compression and free cooling chillers. The performance of cooling systems depends on its part load performance and its condensing temperature, which are often unknown. Recorded energy data remains unused and manufacturers' data significantly differs from the real performance. For this purpose, manufacturer and real data are combined and continuously adapted to form partial load curve models. This study applied a predictive optimization algorithm to calculate the optimal operating conditions of multiple chillers. A sprinkler tank offers the opportunity to store cold-water for later utilisation. This potential is used to show the load shifting potential of the cooling system by using a variable electricity price as an input parameter of the optimisation. The set points from the optimisation have been continuously validated by a dynamic simulation. Finally, a case study of a plastic processing company evaluated different scenarios against the status quo. Applying an optimal chiller loading and charging strategy of a sprinkler tank increased the energy efficiency of up to 40 % during colder and around 17% during warmer periods. The total energy savings highly depended on the weather conditions. For the consider fluctuations, the electricity price had only a minor effect.
Název v anglickém jazyce
Predictive Simulation-based Optimisation of Cooling System Including a Sprinkler Tank
Popis výsledku anglicky
Prerequisite for an efficient cooling energy system is the knowledge and the optimal combination of different operating conditions of individual compression and free cooling chillers. The performance of cooling systems depends on its part load performance and its condensing temperature, which are often unknown. Recorded energy data remains unused and manufacturers' data significantly differs from the real performance. For this purpose, manufacturer and real data are combined and continuously adapted to form partial load curve models. This study applied a predictive optimization algorithm to calculate the optimal operating conditions of multiple chillers. A sprinkler tank offers the opportunity to store cold-water for later utilisation. This potential is used to show the load shifting potential of the cooling system by using a variable electricity price as an input parameter of the optimisation. The set points from the optimisation have been continuously validated by a dynamic simulation. Finally, a case study of a plastic processing company evaluated different scenarios against the status quo. Applying an optimal chiller loading and charging strategy of a sprinkler tank increased the energy efficiency of up to 40 % during colder and around 17% during warmer periods. The total energy savings highly depended on the weather conditions. For the consider fluctuations, the electricity price had only a minor effect.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20402 - Chemical process engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Laboratoř integrace procesů pro trvalou udržitelnost</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Chemical Engineering Transactions
ISBN
978-88-95608-67-9
ISSN
2283-9216
e-ISSN
—
Počet stran výsledku
6
Strana od-do
349-354
Název nakladatele
Italian Association of Chemical Engineering - AIDIC
Místo vydání
Neuveden
Místo konání akce
Prague
Datum konání akce
25. 8. 2018
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—