Comparison of methods for determining the ferrite content in duplex cast steels
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F19%3APU132387" target="_blank" >RIV/00216305:26210/19:PU132387 - isvavai.cz</a>
Výsledek na webu
<a href="http://yadda.icm.edu.pl/yadda/element/bwmeta1.element.baztech-d1e89b84-120e-41a1-b94b-25bbf2a3a77e" target="_blank" >http://yadda.icm.edu.pl/yadda/element/bwmeta1.element.baztech-d1e89b84-120e-41a1-b94b-25bbf2a3a77e</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.24425/afe.2019.127121" target="_blank" >10.24425/afe.2019.127121</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of methods for determining the ferrite content in duplex cast steels
Popis výsledku v původním jazyce
The paper is concerned with comparing the methods for determining the ferrite content in castings from duplex stainless steels. It uses Schaeffler diagram, empirical formula based calculation, image analysis of metallographic sample, X-ray diffraction and measurement with a feritscope. The influence of wall thickness of the casting on the ferrite content was tested too. The results of the experiments show that the casting thickness of 25 or 60 mm does not have a significant effect on the measured amount of ferrite. The image analysis of metallographic sample and the measurement with the feritscope appear to be the most suitable methods. On the contrary, predictive methods, such as Schaeffler diagram or empirical formula based calculation are only indicative and cannot replace the real measurements. X-ray diffraction seems to be the least suitable measuring method. Values of ferrite content measured in such a way often deviated from the values measured by image analysis and with feritscope.
Název v anglickém jazyce
Comparison of methods for determining the ferrite content in duplex cast steels
Popis výsledku anglicky
The paper is concerned with comparing the methods for determining the ferrite content in castings from duplex stainless steels. It uses Schaeffler diagram, empirical formula based calculation, image analysis of metallographic sample, X-ray diffraction and measurement with a feritscope. The influence of wall thickness of the casting on the ferrite content was tested too. The results of the experiments show that the casting thickness of 25 or 60 mm does not have a significant effect on the measured amount of ferrite. The image analysis of metallographic sample and the measurement with the feritscope appear to be the most suitable methods. On the contrary, predictive methods, such as Schaeffler diagram or empirical formula based calculation are only indicative and cannot replace the real measurements. X-ray diffraction seems to be the least suitable measuring method. Values of ferrite content measured in such a way often deviated from the values measured by image analysis and with feritscope.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20501 - Materials engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/TH02020076" target="_blank" >TH02020076: Výzkum a vývoj odlévání a svařování masivních odlitků z duplexních ocelí</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Archives of foundry engineering
ISSN
1897-3310
e-ISSN
2299-2944
Svazek periodika
19
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
6
Strana od-do
85-90
Kód UT WoS článku
000469410900015
EID výsledku v databázi Scopus
2-s2.0-85066398200