Comparison of Fibre-Based Phase Doppler Analysers
Popis výsledku v původním jazyce
Laser diagnostics techniques are widely used in experimental fluid mechanics. By far the most widely used systems for getting spatial velocity fields and turbulence data are laser Doppler anemometers (LDA). Further, in the cases of two-phase flows phase Doppler analysers (PDA) are typically chosen to measure the size and velocity of the droplets or bubbles. The PDA system is non-intrusive laser technique with high spatial and temporal resolution. Moreover, the PDA system does not require additional calibration as, for example, hot-wire anemometers. However, with a growing number of PDA users, there is a need for verification of the results among the workplaces and systems themselves. The current paper deals with the comparison of two fibre-based PDA systems. The main scope of the investigation is an evaluation of the system's age and the influence of lasers type. One of the systems is older, operated with Argon-Ion laser and the second one is brand new equipped with Diode-pumped solid-state lasers. Bo
Název v anglickém jazyce
Comparison of Fibre-Based Phase Doppler Analysers
Popis výsledku anglicky
Laser diagnostics techniques are widely used in experimental fluid mechanics. By far the most widely used systems for getting spatial velocity fields and turbulence data are laser Doppler anemometers (LDA). Further, in the cases of two-phase flows phase Doppler analysers (PDA) are typically chosen to measure the size and velocity of the droplets or bubbles. The PDA system is non-intrusive laser technique with high spatial and temporal resolution. Moreover, the PDA system does not require additional calibration as, for example, hot-wire anemometers. However, with a growing number of PDA users, there is a need for verification of the results among the workplaces and systems themselves. The current paper deals with the comparison of two fibre-based PDA systems. The main scope of the investigation is an evaluation of the system's age and the influence of lasers type. One of the systems is older, operated with Argon-Ion laser and the second one is brand new equipped with Diode-pumped solid-state lasers. Bo
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10305 - Fluids and plasma physics (including surface physics)
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů