THERMAL CONDUCTANCE EXPERIMENTAL DETERMINATION IN SIMULATED DEEP SPACE ENVIRONMENT
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F20%3APU138266" target="_blank" >RIV/00216305:26210/20:PU138266 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.engmech.cz/improc/2020/322.pdf" target="_blank" >https://www.engmech.cz/improc/2020/322.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.21495/5896-3-322" target="_blank" >10.21495/5896-3-322</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
THERMAL CONDUCTANCE EXPERIMENTAL DETERMINATION IN SIMULATED DEEP SPACE ENVIRONMENT
Popis výsledku v původním jazyce
Thermal conductance measurement in the simulated deep space and Martian atmosphere conditions is one of the key objectives in the Miniaturized Heat Switch redesign and development project. The experiments are to be performed in the thermo-vacuum test chamber, once the measurement interference and accuracy are determined. For this purpose, calibration specimens were manufactured and tested. The tests were performed under 10(-3) Pa pressure, according to the qualification requirements. The data were used to design test apparatus's thermal model, capable of specimens thermal conductance evaluation. The thermal model results identified potential refinement parameters. The model applicability should be verified once a sufficient amount of data is evaluated.
Název v anglickém jazyce
THERMAL CONDUCTANCE EXPERIMENTAL DETERMINATION IN SIMULATED DEEP SPACE ENVIRONMENT
Popis výsledku anglicky
Thermal conductance measurement in the simulated deep space and Martian atmosphere conditions is one of the key objectives in the Miniaturized Heat Switch redesign and development project. The experiments are to be performed in the thermo-vacuum test chamber, once the measurement interference and accuracy are determined. For this purpose, calibration specimens were manufactured and tested. The tests were performed under 10(-3) Pa pressure, according to the qualification requirements. The data were used to design test apparatus's thermal model, capable of specimens thermal conductance evaluation. The thermal model results identified potential refinement parameters. The model applicability should be verified once a sufficient amount of data is evaluated.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20304 - Aerospace engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the Engineering Mechanics 2020
ISBN
978-80-214-5896-3
ISSN
1805-8248
e-ISSN
—
Počet stran výsledku
4
Strana od-do
322-325
Název nakladatele
Brno University of Technology
Místo vydání
Brno
Místo konání akce
Online
Datum konání akce
24. 11. 2020
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000667956100073