Popis výsledku v původním jazyce
Refineries are big consumers of energy and hydrogen. However, most current studies focus on the optimisation of H2 Network or Heat Integration in refineries H2 and heat are not considered together. The presented paper proposes a hierarchical targeting method for H2 and heat using the Onion Model to solve this problem. H2 networks belong to the inner layer of the onion, and heat recovery to the outer layer. The targets for H2 recovery are obtained, followed by Heat Exchanger Network targeting. A case study of an oil refinery shows that both H2 and energy can be significantly reduced. This study shows an approach to achieve a synergy of targeting H2 and heat recovery. It has great significance to the energy-saving and emission reduction of an oil refinery. © 2020, AIDIC Servizi S.r.l.
Název v anglickém jazyce
Hierarchical Targeting of Hydrogen Network System and Heat Integration in a Refinery
Popis výsledku anglicky
Refineries are big consumers of energy and hydrogen. However, most current studies focus on the optimisation of H2 Network or Heat Integration in refineries H2 and heat are not considered together. The presented paper proposes a hierarchical targeting method for H2 and heat using the Onion Model to solve this problem. H2 networks belong to the inner layer of the onion, and heat recovery to the outer layer. The targets for H2 recovery are obtained, followed by Heat Exchanger Network targeting. A case study of an oil refinery shows that both H2 and energy can be significantly reduced. This study shows an approach to achieve a synergy of targeting H2 and heat recovery. It has great significance to the energy-saving and emission reduction of an oil refinery. © 2020, AIDIC Servizi S.r.l.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
<a href="/cs/project/EF15_003%2F0000456" target="_blank" >EF15_003/0000456: Laboratoř integrace procesů pro trvalou udržitelnost</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Chemical Engineering Transactions
ISSN
2283-9216
e-ISSN
—
Svazek periodika
neuveden
Číslo periodika v rámci svazku
81
Stát vydavatele periodika
IT - Italská republika
Počet stran výsledku
6
Strana od-do
217-222
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-85092086210