Hydrodynamic response time of magnetorheological fluid in valve mode: an initial study
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F21%3APU141660" target="_blank" >RIV/00216305:26210/21:PU141660 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1757-899X/1186/1/012002" target="_blank" >https://iopscience.iop.org/article/10.1088/1757-899X/1186/1/012002</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/1186/1/012002" target="_blank" >10.1088/1757-899X/1186/1/012002</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Hydrodynamic response time of magnetorheological fluid in valve mode: an initial study
Popis výsledku v původním jazyce
The transient behaviour of magnetorheological (MR) damper is a very important parameter affecting the performance of this technology in modern semi-actively controlled suspension systems. Currently, the transient behaviour of the MR damper is limited by dynamics of the MR fluid (MRF) itself. The significant part of MRF response time is a hydrodynamic response time which is connected with transient rheology and development of velocity profile in the slit gap. In this paper, the method for measuring the hydrodynamic response time of MRF operating in valve mode is presented. The hydrodynamic response time of MRF-132DG achieved value of τ90 = 0.78 ms for H = 17.5 kA/m a value of τ90 = 0.65 ms for H = 34 kA/m for given geometry of gap. The difference between model and experiment is lower in higher yield stresses of MRF.
Název v anglickém jazyce
Hydrodynamic response time of magnetorheological fluid in valve mode: an initial study
Popis výsledku anglicky
The transient behaviour of magnetorheological (MR) damper is a very important parameter affecting the performance of this technology in modern semi-actively controlled suspension systems. Currently, the transient behaviour of the MR damper is limited by dynamics of the MR fluid (MRF) itself. The significant part of MRF response time is a hydrodynamic response time which is connected with transient rheology and development of velocity profile in the slit gap. In this paper, the method for measuring the hydrodynamic response time of MRF operating in valve mode is presented. The hydrodynamic response time of MRF-132DG achieved value of τ90 = 0.78 ms for H = 17.5 kA/m a value of τ90 = 0.65 ms for H = 34 kA/m for given geometry of gap. The difference between model and experiment is lower in higher yield stresses of MRF.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GJ20-23261Y" target="_blank" >GJ20-23261Y: Studium časové odezvy magnetoreologické kapaliny</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
World Symposium on Smart Materials and Applications (WSSMA 2021) 16th-18th July 2021, Bangkok, Thailand
ISBN
—
ISSN
1757-899X
e-ISSN
—
Počet stran výsledku
7
Strana od-do
1-7
Název nakladatele
IOP Publishing
Místo vydání
neuveden
Místo konání akce
Bangkok
Datum konání akce
16. 6. 2021