Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F22%3APU144803" target="_blank" >RIV/00216305:26210/22:PU144803 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/22:00076312 RIV/00216224:14110/22:00127176
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0169260722002164" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0169260722002164</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.cmpb.2022.106834" target="_blank" >10.1016/j.cmpb.2022.106834</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method
Popis výsledku v původním jazyce
Background and objective: Total knee arthroplasty (TKA) with modern all-polyethylene tibial (APT) components has shown high long-term survival rates and comparable results to those with metal-backed tibial components. Nevertheless, APT components are primarily recommended for older and low-demand patients. There are no evidence-based biomechanical guidelines for orthopaedic surgeons to determine the appropriate lower age limit for implantation of APT components. A biomechanical analysis was assumed to be suitable to evaluate the clinical results in patients under 70 years. The scope of this study was to determine biomechanically the appropriate lower age limit for implantation of APT components.& nbsp;Methods: To generate data of the highest possible quality, the geometry of the computational models was created based on computed tomography (CT) images of a representative patient. The cortical bone tissue model distinguishes the change in mechanical properties described in three parts from the tibial cut. The cancellous bone material model has a heterogeneous distribution of mechanical properties. The values used to determine the material properties of the tissues were obtained from measurements of a CT dataset comprising 45 patients.& nbsp;Results: Computational modeling showed that in the majority of the periprosthetic volume, the von Mises strain equivalent ranges from 200 to 2700 its; these strain values induce bone modeling and remodeling. The highest measured deformation value was 2910 its. There was no significant difference in the induced mechanical response between bone models of the 60-year and 70-year age groups, and there was < 3% difference from the 65-year age group.& nbsp;Conclusions: Considering in silico limitations, we suggest that APT components could be conveniently used on a bone with mechanical properties of the examined age categories. Under defined loading conditions, implantation of TKA with APT components is expected to induce modeling and r
Název v anglickém jazyce
Biomechanical analysis of all-polyethylene total knee arthroplasty on periprosthetic tibia using the finite element method
Popis výsledku anglicky
Background and objective: Total knee arthroplasty (TKA) with modern all-polyethylene tibial (APT) components has shown high long-term survival rates and comparable results to those with metal-backed tibial components. Nevertheless, APT components are primarily recommended for older and low-demand patients. There are no evidence-based biomechanical guidelines for orthopaedic surgeons to determine the appropriate lower age limit for implantation of APT components. A biomechanical analysis was assumed to be suitable to evaluate the clinical results in patients under 70 years. The scope of this study was to determine biomechanically the appropriate lower age limit for implantation of APT components.& nbsp;Methods: To generate data of the highest possible quality, the geometry of the computational models was created based on computed tomography (CT) images of a representative patient. The cortical bone tissue model distinguishes the change in mechanical properties described in three parts from the tibial cut. The cancellous bone material model has a heterogeneous distribution of mechanical properties. The values used to determine the material properties of the tissues were obtained from measurements of a CT dataset comprising 45 patients.& nbsp;Results: Computational modeling showed that in the majority of the periprosthetic volume, the von Mises strain equivalent ranges from 200 to 2700 its; these strain values induce bone modeling and remodeling. The highest measured deformation value was 2910 its. There was no significant difference in the induced mechanical response between bone models of the 60-year and 70-year age groups, and there was < 3% difference from the 65-year age group.& nbsp;Conclusions: Considering in silico limitations, we suggest that APT components could be conveniently used on a bone with mechanical properties of the examined age categories. Under defined loading conditions, implantation of TKA with APT components is expected to induce modeling and r
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE
ISSN
0169-2607
e-ISSN
1872-7565
Svazek periodika
220
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
1-9
Kód UT WoS článku
000800357800013
EID výsledku v databázi Scopus
2-s2.0-85129266278