Effect of blade layout on performance of low specific speed pump operating in turbine mode
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F22%3APU144881" target="_blank" >RIV/00216305:26210/22:PU144881 - isvavai.cz</a>
Výsledek na webu
<a href="https://iopscience.iop.org/article/10.1088/1755-1315/1079/1/012071" target="_blank" >https://iopscience.iop.org/article/10.1088/1755-1315/1079/1/012071</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1755-1315/1079/1/012071" target="_blank" >10.1088/1755-1315/1079/1/012071</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Effect of blade layout on performance of low specific speed pump operating in turbine mode
Popis výsledku v původním jazyce
The very low specific speed pump (nq = 8.9) operated in turbine mode was analyzed. The experimental and numerical studies were carried out in order to show effect of different blade layout on pump-as-turbine (PaT) performance. In total three different impellers were analyzed. One impeller consisting of four main blades and two impellers consisting of four main blades and different arrangement of splitter blades. Either single splitter blade or two splitter blades are placed between each of main blades. While measurements pointed out the main PaT performance, the simulations enable to analyze internal flow fields and point out the mechanisms of performance variation using different impellers. The main aim of this study is to clarify usability of very low specific speed pump for energy recovery in terms of pump as turbine operation or for storage capability in terms of pump-turbine.
Název v anglickém jazyce
Effect of blade layout on performance of low specific speed pump operating in turbine mode
Popis výsledku anglicky
The very low specific speed pump (nq = 8.9) operated in turbine mode was analyzed. The experimental and numerical studies were carried out in order to show effect of different blade layout on pump-as-turbine (PaT) performance. In total three different impellers were analyzed. One impeller consisting of four main blades and two impellers consisting of four main blades and different arrangement of splitter blades. Either single splitter blade or two splitter blades are placed between each of main blades. While measurements pointed out the main PaT performance, the simulations enable to analyze internal flow fields and point out the mechanisms of performance variation using different impellers. The main aim of this study is to clarify usability of very low specific speed pump for energy recovery in terms of pump as turbine operation or for storage capability in terms of pump-turbine.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
<a href="/cs/project/EF16_026%2F0008392" target="_blank" >EF16_026/0008392: Výpočtové simulace pro efektivní nízkoemisní energetiku</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
IOP Conference Series: Earth and Environmental Science
ISBN
—
ISSN
1755-1315
e-ISSN
—
Počet stran výsledku
10
Strana od-do
1-10
Název nakladatele
Neuveden
Místo vydání
neuveden
Místo konání akce
Trondheim
Datum konání akce
26. 6. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—