Importance of experimental evaluation of structural parameters for constitutive modelling of aorta
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F23%3APU146924" target="_blank" >RIV/00216305:26210/23:PU146924 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00159816:_____/23:00077771 RIV/00216224:14110/23:00134025
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1751616122005203" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1751616122005203</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmbbm.2022.105615" target="_blank" >10.1016/j.jmbbm.2022.105615</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Importance of experimental evaluation of structural parameters for constitutive modelling of aorta
Popis výsledku v původním jazyce
The study compares stresses and strains in the aortic wall derived using different constitutive models for various stress-strain conditions. Structure-based constitutive models with two fibre families with (GOH) and without (HGO) dispersion of collagen fibres are compared. The constitutive models were fitted to data from equibiaxial tension tests of two separated layers of the porcine aortic wall. The initial fit was evaluated with unrestricted parameters and subsequently, the mean angles of the fibre families and the angular dispersion were fixed to the values obtained from histology. Surprisingly, none of the tested models was capable to provide a good quality fit with histologically obtained structural parameters. Fitting the HGO model to experimental data resulted in two fibre families under angles close to +/- 45 degrees, while the GOH model resulted in a nearly isotropic fibre distribution. These results indicate that both of these models suffer from the absence of isotropic strain stiffening. After having modified both models with corresponding additional members based on the Yeoh model of matrix, we obtained a perfect fit to the measured data while keeping the structural histology-based parameters. Finally, significant differences in compliance and resulting stresses and strains between different models are shown by means of simulations of uniaxial tension test, equibiaxial tension tests and inflation of the aorta.
Název v anglickém jazyce
Importance of experimental evaluation of structural parameters for constitutive modelling of aorta
Popis výsledku anglicky
The study compares stresses and strains in the aortic wall derived using different constitutive models for various stress-strain conditions. Structure-based constitutive models with two fibre families with (GOH) and without (HGO) dispersion of collagen fibres are compared. The constitutive models were fitted to data from equibiaxial tension tests of two separated layers of the porcine aortic wall. The initial fit was evaluated with unrestricted parameters and subsequently, the mean angles of the fibre families and the angular dispersion were fixed to the values obtained from histology. Surprisingly, none of the tested models was capable to provide a good quality fit with histologically obtained structural parameters. Fitting the HGO model to experimental data resulted in two fibre families under angles close to +/- 45 degrees, while the GOH model resulted in a nearly isotropic fibre distribution. These results indicate that both of these models suffer from the absence of isotropic strain stiffening. After having modified both models with corresponding additional members based on the Yeoh model of matrix, we obtained a perfect fit to the measured data while keeping the structural histology-based parameters. Finally, significant differences in compliance and resulting stresses and strains between different models are shown by means of simulations of uniaxial tension test, equibiaxial tension tests and inflation of the aorta.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-21935S" target="_blank" >GA21-21935S: Výpočtové modelování pulzačního proudění v poddajných trubicích s aplikací na tandemovou stenózu karotidy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of the mechanical behavior of biomedical materials
ISSN
1751-6161
e-ISSN
1878-0180
Svazek periodika
138
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
8
Strana od-do
„105615-1“-„105615-8“
Kód UT WoS článku
000899579700003
EID výsledku v databázi Scopus
2-s2.0-85143656828