Determination of thermal contact resistance in thermo-vacuum chamber experiments
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F23%3APU150848" target="_blank" >RIV/00216305:26210/23:PU150848 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.scopus.com/record/display.uri?eid=2-s2.0-85187988272&origin=resultslist&sort=plf-f&src=s&sid=d0793b63fb226882f45b4ea4527a3c69&sot=b&sdt=cl&cluster=scosubjabbr%2C%22ENGI%22%2Ct&s=FIRSTAUTH%28lazar%29&sl=20&sessionSearchId=d0793b63fb226882f45b4" target="_blank" >https://www.scopus.com/record/display.uri?eid=2-s2.0-85187988272&origin=resultslist&sort=plf-f&src=s&sid=d0793b63fb226882f45b4ea4527a3c69&sot=b&sdt=cl&cluster=scosubjabbr%2C%22ENGI%22%2Ct&s=FIRSTAUTH%28lazar%29&sl=20&sessionSearchId=d0793b63fb226882f45b4</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of thermal contact resistance in thermo-vacuum chamber experiments
Popis výsledku v původním jazyce
Thermal contact resistance (TCR) caused by surface imperfections results in a reduced heat transfer rate on the interface of two solids in contact. The exact prediction of these resistances may enhance the accuracy of the thermal conductance measurements in a thermo-vacuum chamber. Such an enhancement is crucial for the development and performance testing of the Miniaturized Heat Switch – a passive thermal management unit for satellites or robotic missions. This study presents an experimental investigation of low contact-pressure TCR within thermo-vacuum chamber measurement. We will use a custom-built experimental setup to measure the steady-state temperature difference across the calibration specimen and chamber interface while varying the applied heat load. The results quantify the effect of low contact pressure TCR within the experiments and provide insights into the design of heat transfer interfaces. This knowledge may be also applied in heat switch technology that relies on efficient heat transfer.
Název v anglickém jazyce
Determination of thermal contact resistance in thermo-vacuum chamber experiments
Popis výsledku anglicky
Thermal contact resistance (TCR) caused by surface imperfections results in a reduced heat transfer rate on the interface of two solids in contact. The exact prediction of these resistances may enhance the accuracy of the thermal conductance measurements in a thermo-vacuum chamber. Such an enhancement is crucial for the development and performance testing of the Miniaturized Heat Switch – a passive thermal management unit for satellites or robotic missions. This study presents an experimental investigation of low contact-pressure TCR within thermo-vacuum chamber measurement. We will use a custom-built experimental setup to measure the steady-state temperature difference across the calibration specimen and chamber interface while varying the applied heat load. The results quantify the effect of low contact pressure TCR within the experiments and provide insights into the design of heat transfer interfaces. This knowledge may be also applied in heat switch technology that relies on efficient heat transfer.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20304 - Aerospace engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the International Astronautical Congress, IAC
ISBN
—
ISSN
0074-1795
e-ISSN
—
Počet stran výsledku
5
Strana od-do
„“-„“
Název nakladatele
International Astronautical Federation
Místo vydání
Baku, Azerbaijan
Místo konání akce
Baku, Azerbaijan
Datum konání akce
2. 10. 2023
Typ akce podle státní příslušnosti
WRD - Celosvětová akce