Performance of vacuum-insulated central pipes for deep borehole heat exchangers in geothermal systems
Popis výsledku v původním jazyce
Geothermal energy is considered a promising future energy prospect, with the geothermal well outlet temperature being one of the important parameters affecting possible utilization options. For ground source heat pump applications or direct district heating, using lower temperatures can be acceptable. However, efficient electricity production requires a higher enthalpy gradient, which cannot be achieved without high temperature at the wellhead. The selection of the dry co-axial close-loop deep borehole systems (DBHE) may be, in some cases, very beneficial. The operating performance of co-axial DBHE can be optimized if the undesired heat transfer between the central pipe and annular fluid zones is minimized. Therefore, the operational performance of such a system depends strongly on the high thermal resistance of the central pipe. The most common option would be a low thermal conductivity material, such as high-density polyethylene (HDPE). In addition, vacuum-insulated tubing (VIT) used as the central pipe could be considered. The article presents results from the study aimed at the comparison of the homogeneous central pipe made of HDPE material and the gap-insulated central pipe. In the study, various air pressure levels as well as variations of surface emissivity were examined to reveal the effect on the heat transfer between the fluid channels. The simulation has been performed using a new purposely developed WellTH simulation software. A coaxial heat exchanger system using a VIT outperforms significantly the heat exchanger with an HDPE for deep geothermal wells. However, this advantage diminishes for shallow wells and therefore this tendency should be considered in the design stage.
Název v anglickém jazyce
Performance of vacuum-insulated central pipes for deep borehole heat exchangers in geothermal systems
Popis výsledku anglicky
Geothermal energy is considered a promising future energy prospect, with the geothermal well outlet temperature being one of the important parameters affecting possible utilization options. For ground source heat pump applications or direct district heating, using lower temperatures can be acceptable. However, efficient electricity production requires a higher enthalpy gradient, which cannot be achieved without high temperature at the wellhead. The selection of the dry co-axial close-loop deep borehole systems (DBHE) may be, in some cases, very beneficial. The operating performance of co-axial DBHE can be optimized if the undesired heat transfer between the central pipe and annular fluid zones is minimized. Therefore, the operational performance of such a system depends strongly on the high thermal resistance of the central pipe. The most common option would be a low thermal conductivity material, such as high-density polyethylene (HDPE). In addition, vacuum-insulated tubing (VIT) used as the central pipe could be considered. The article presents results from the study aimed at the comparison of the homogeneous central pipe made of HDPE material and the gap-insulated central pipe. In the study, various air pressure levels as well as variations of surface emissivity were examined to reveal the effect on the heat transfer between the fluid channels. The simulation has been performed using a new purposely developed WellTH simulation software. A coaxial heat exchanger system using a VIT outperforms significantly the heat exchanger with an HDPE for deep geothermal wells. However, this advantage diminishes for shallow wells and therefore this tendency should be considered in the design stage.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Low Carbon Technologies
ISSN
1748-1317
e-ISSN
—
Svazek periodika
19
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
18
Strana od-do
2068-2085
Kód UT WoS článku
001306644200001
EID výsledku v databázi Scopus
2-s2.0-85203627557