Evaporative cooling can be an answer to the growing global demand for energy efficient and sustainable air conditioning. Direct evaporative cooling is the traditional method of cooling air to wet-bulb temperature. Indirect evaporative cooling uses heat exchangers with wet and dry channels to cool air indirectly, avoiding an increase in humidity. The Maisotsenko cycle is a dew point indirect evaporative cooling that allows air to be cooled below wet-bulb temperature using a heat and mass exchanger with a coupled wet and dry channel. It can be used as a stand-alone system, or as coupled with traditional refrigerantbased cooling systems, or as a heat recovery process to improve the efficiency in the power industry applications. A Pythonbased computational tool for simulating of 1D heat and mass transfer in the Maisotsenko cycle is presented here. It uses a spatially discretised differential equation solver and a psychrometric chart. The 1D model and experimental data from the study of Pakari were used as a reference for the initial testing. The comparison results are promising, suggesting a potential application in the design of sustainable cooling.
Název v anglickém jazyce
Sustainable air conditioning with a focus on evaporative cooling and the Maisotsenko cycle
Popis výsledku anglicky
Evaporative cooling can be an answer to the growing global demand for energy efficient and sustainable air conditioning. Direct evaporative cooling is the traditional method of cooling air to wet-bulb temperature. Indirect evaporative cooling uses heat exchangers with wet and dry channels to cool air indirectly, avoiding an increase in humidity. The Maisotsenko cycle is a dew point indirect evaporative cooling that allows air to be cooled below wet-bulb temperature using a heat and mass exchanger with a coupled wet and dry channel. It can be used as a stand-alone system, or as coupled with traditional refrigerantbased cooling systems, or as a heat recovery process to improve the efficiency in the power industry applications. A Pythonbased computational tool for simulating of 1D heat and mass transfer in the Maisotsenko cycle is presented here. It uses a spatially discretised differential equation solver and a psychrometric chart. The 1D model and experimental data from the study of Pakari were used as a reference for the initial testing. The comparison results are promising, suggesting a potential application in the design of sustainable cooling.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
<a href="/cs/project/EH22_008%2F0004634" target="_blank" >EH22_008/0004634: Strojní inženýrství biologických a bioinspirovaných systémů</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Archives of Thermodynamics
ISSN
1231-0956
e-ISSN
2083-6023
Svazek periodika
46
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
PL - Polská republika
Počet stran výsledku
11
Strana od-do
111-121
Kód UT WoS článku
001532302900011
EID výsledku v databázi Scopus
2-s2.0-105010444076