CASE STUDY: THE INFLUENCE OF MACHINE TOOL CONDITION CHANGES ON MEASUREMENT ACCURACY USING A WORKPIECE PROBE
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F26%3A0199875" target="_blank" >RIV/00216305:26210/26:0199875 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.mmscience.eu/journal/issues/december-2025/articles/case-study-the-influence-of-machine-tool-condition-changes-on-measurement-accuracy-using-a-workpiece-probe" target="_blank" >https://www.mmscience.eu/journal/issues/december-2025/articles/case-study-the-influence-of-machine-tool-condition-changes-on-measurement-accuracy-using-a-workpiece-probe</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.17973/MMSJ.2025_12_2025155" target="_blank" >10.17973/MMSJ.2025_12_2025155</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
CASE STUDY: THE INFLUENCE OF MACHINE TOOL CONDITION CHANGES ON MEASUREMENT ACCURACY USING A WORKPIECE PROBE
Popis výsledku v původním jazyce
This study evaluates the measurement system capability of a three-axis vertical milling center under three machine conditions with varying positioning accuracy. Using a laser interferometer, probe, and calibrated KOBA artifact, length measurements were taken and corrected for thermal expansion. Results show that while none of the machine states achieved full capability for the given 0.015 mm tolerance, states 1 and 3 were suitable for conformity assessment. State 2, despite better deviation results, was limited by significant nonlinearity, increasing uncertainty. The importance of linearity in evaluating measurement system capability is highlighted, particularly when calculating linearity uncertainty.
Název v anglickém jazyce
CASE STUDY: THE INFLUENCE OF MACHINE TOOL CONDITION CHANGES ON MEASUREMENT ACCURACY USING A WORKPIECE PROBE
Popis výsledku anglicky
This study evaluates the measurement system capability of a three-axis vertical milling center under three machine conditions with varying positioning accuracy. Using a laser interferometer, probe, and calibrated KOBA artifact, length measurements were taken and corrected for thermal expansion. Results show that while none of the machine states achieved full capability for the given 0.015 mm tolerance, states 1 and 3 were suitable for conformity assessment. State 2, despite better deviation results, was limited by significant nonlinearity, increasing uncertainty. The importance of linearity in evaluating measurement system capability is highlighted, particularly when calculating linearity uncertainty.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
MM Science Journal
ISSN
1803-1269
e-ISSN
1805-0476
Svazek periodika
—
Číslo periodika v rámci svazku
December 2025
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
7
Strana od-do
9088-9094
Kód UT WoS článku
001638122400001
EID výsledku v databázi Scopus
2-s2.0-105025912297