Efficient enhancement in thermal power plant using wastewater and flue gas streams
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F26%3A0201487" target="_blank" >RIV/00216305:26210/26:0201487 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0360544225007303#ack0010a" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0360544225007303#ack0010a</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.energy.2025.135088" target="_blank" >10.1016/j.energy.2025.135088</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Efficient enhancement in thermal power plant using wastewater and flue gas streams
Popis výsledku v původním jazyce
This paper deals with the design of an efficient and improved boiler and steam section of 250 MW TPP which is targeted using SuperTarget. Minimum utility requirements for both hot and cold utilities come out to be 563.69 MW and 316.92 MW. Pinch cum heuristic approach is used with six different retrofitting cases for heat recovery of flue gas and boiler blowdown of TPP because proposed HEN by SuperTarget is not feasible and very expensive. The proposed retrofitting cases are evaluated based on energy saving, enhancement in TPP efficiency and CO2 reduction. The novel heuristic approach shows that a saving in DM water of 16.8-18.1 t/h in six proposed cases. The energy savings are found to be much higher with the optimum case in comparison to other cases. The retrofitting cases demonstrate that the reductions in higher-stage extractions leads to increase power generation, and enhance efficiency of TPP. This energy utilization is targeted to contribute more overall performance and sustainability of the TPP. An efficiency improvement of 0.5 % was found in the optimum case compared to the existing system. The results are consistent and compared with that of published literature, implying that the proposed approach is viable.
Název v anglickém jazyce
Efficient enhancement in thermal power plant using wastewater and flue gas streams
Popis výsledku anglicky
This paper deals with the design of an efficient and improved boiler and steam section of 250 MW TPP which is targeted using SuperTarget. Minimum utility requirements for both hot and cold utilities come out to be 563.69 MW and 316.92 MW. Pinch cum heuristic approach is used with six different retrofitting cases for heat recovery of flue gas and boiler blowdown of TPP because proposed HEN by SuperTarget is not feasible and very expensive. The proposed retrofitting cases are evaluated based on energy saving, enhancement in TPP efficiency and CO2 reduction. The novel heuristic approach shows that a saving in DM water of 16.8-18.1 t/h in six proposed cases. The energy savings are found to be much higher with the optimum case in comparison to other cases. The retrofitting cases demonstrate that the reductions in higher-stage extractions leads to increase power generation, and enhance efficiency of TPP. This energy utilization is targeted to contribute more overall performance and sustainability of the TPP. An efficiency improvement of 0.5 % was found in the optimum case compared to the existing system. The results are consistent and compared with that of published literature, implying that the proposed approach is viable.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20303 - Thermodynamics
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Energy
ISSN
0360-5442
e-ISSN
1873-6785
Svazek periodika
319
Číslo periodika v rámci svazku
0360-5442
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
15
Strana od-do
1-15
Kód UT WoS článku
001431951200001
EID výsledku v databázi Scopus
2-s2.0-85217904402