On-line Fuzzy Parameters Setting of Predictive Controller
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F00%3A43700029" target="_blank" >RIV/00216305:26220/00:43700029 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
On-line Fuzzy Parameters Setting of Predictive Controller
Popis výsledku v původním jazyce
Classical model based predictive regulation sets the action signal magnitude in a way that ensures, that the chosen cost function will reach its minimum, which means, that the proper cost function parameters setting is crucial for the shape of transient.These parameters are usually constants that do not change their value in the course of regulation. However, given the actual condition of the regulation, their change can improve the quality of the transient. This solution reduces the adverse effects caused by the inexact model of the plant or short predictive horizon (short sample period) with regard to the length of the transient. This can occur when we use adaptive predictive control, where the dynamics and consequently also the duration of the transient are not constant.
Název v anglickém jazyce
On-line Fuzzy Parameters Setting of Predictive Controller
Popis výsledku anglicky
Classical model based predictive regulation sets the action signal magnitude in a way that ensures, that the chosen cost function will reach its minimum, which means, that the proper cost function parameters setting is crucial for the shape of transient.These parameters are usually constants that do not change their value in the course of regulation. However, given the actual condition of the regulation, their change can improve the quality of the transient. This solution reduces the adverse effects caused by the inexact model of the plant or short predictive horizon (short sample period) with regard to the length of the transient. This can occur when we use adaptive predictive control, where the dynamics and consequently also the duration of the transient are not constant.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2000
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of East West Fuzzy Colloquium 2000, Heft 64
ISBN
3-00-006723-X
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
—
Název nakladatele
IPM, University of Applied Science, Zittau
Místo vydání
Germany
Místo konání akce
—
Datum konání akce
—
Typ akce podle státní příslušnosti
—
Kód UT WoS článku
—