Modified measuring method for conductometric chemical sensors
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F02%3APU29221" target="_blank" >RIV/00216305:26220/02:PU29221 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Modified measuring method for conductometric chemical sensors
Popis výsledku v původním jazyce
Many transducers without electronic circuits are already fabricated. Because a miniaturisation of sensors are required, only an on-chip implementation can be accepted. Our research is focused on precise electronic detectors for conductometric sensors. Results of the research show that the conductometric sensor changes a cell constant correction under variation of a concentration of a liquid solution. It is remarkable for IDES of a microsensor as a parasitic parallel capacity Cp, which impacts an impedannce responce of the IDES a lot.Our method realised in new progressive technologies as ASIC can be used for all type conductometric sensors as conductivity sensors of liquid solution, biosensors, gas sensors, etc.
Název v anglickém jazyce
Modified measuring method for conductometric chemical sensors
Popis výsledku anglicky
Many transducers without electronic circuits are already fabricated. Because a miniaturisation of sensors are required, only an on-chip implementation can be accepted. Our research is focused on precise electronic detectors for conductometric sensors. Results of the research show that the conductometric sensor changes a cell constant correction under variation of a concentration of a liquid solution. It is remarkable for IDES of a microsensor as a parasitic parallel capacity Cp, which impacts an impedannce responce of the IDES a lot.Our method realised in new progressive technologies as ASIC can be used for all type conductometric sensors as conductivity sensors of liquid solution, biosensors, gas sensors, etc.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JB - Senzory, čidla, měření a regulace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA102%2F00%2F0939" target="_blank" >GA102/00/0939: Integrované inteligentní mikrosenzory a mikrosystémy</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
9th International Meeting on Chemical Sensors
ISBN
—
ISSN
—
e-ISSN
—
Počet stran výsledku
1
Strana od-do
352-352
Název nakladatele
Elsevier Science
Místo vydání
Boston, MA, USA
Místo konání akce
Boston
Datum konání akce
7. 7. 2002
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—