O ortogonalitě elektrokardiografických svodových systémů
Popis výsledku v původním jazyce
The paper deals with evaluating quality of some orthogonal and pseudoorthogonal electrocardiographic lead systems as Frank lead system, signals derived from standard electrocardiographic leads by Levkov?s transform and some signals of the standard 12 lead system that roughly fulfill condition of geometrical orthogonality. The signals of the lead systems were assessed by means of a mathematical criterion of two vector orthogonality which was originally proposed for purposes of electrocardiography and prooved by Netušil. Experiments done with signals of the CSE database of short-time rest ECG records have revealed that the best ECG lead orthogonality has been found for signal sets of I-aVF-V2, and I-III-V2 leads, resp. Unfortunately nearly the worst results were obtained for the widely used Frank orthogonal lead system. It means that this lead system can lead (under some specific conditions) to missing diagnostically important information.
Název v anglickém jazyce
On Orthogonality of Electrocardiographic Lead Systems
Popis výsledku anglicky
The paper deals with evaluating quality of some orthogonal and pseudoorthogonal electrocardiographic lead systems as Frank lead system, signals derived from standard electrocardiographic leads by Levkov?s transform and some signals of the standard 12 lead system that roughly fulfill condition of geometrical orthogonality. The signals of the lead systems were assessed by means of a mathematical criterion of two vector orthogonality which was originally proposed for purposes of electrocardiography and prooved by Netušil. Experiments done with signals of the CSE database of short-time rest ECG records have revealed that the best ECG lead orthogonality has been found for signal sets of I-aVF-V2, and I-III-V2 leads, resp. Unfortunately nearly the worst results were obtained for the widely used Frank orthogonal lead system. It means that this lead system can lead (under some specific conditions) to missing diagnostically important information.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vnitřní lékařství
ISSN
0042-773X
e-ISSN
—
Svazek periodika
48
Číslo periodika v rámci svazku
S1
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
5
Strana od-do
183-187
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—